Chassis Final Connections
With the chassis in place, you are now ready to begin chassis 
connections:
Electrical Shock Hazard
WARNING
Pull out electrical disconnect on front of 
the chassis and turn off all power to the 
unit before servicing.
Failure to do so can result in property 
damage, personal injury and/or death.
Final Installation Checklist
Inspect and ensure that all components and accesso-
ries  have  been  installed  properly  and  that  they  have 
not been damaged during the installation process.
Ensure  that  all  installation  instructions  concerning 
clearances around the unit have been adhered to.
Check to ensure that the unit air filter, indoor coil, and 
outdoor coil are free from any obstructions. 
Ensure that the circuit breaker(s) or fuse(s) and supply 
circuit wire size have been sized correctly.
Check  the  condensate  water  drain(s)  to  ensure  that 
they  are  adequate  for  the  removal  of  condensate 
water, and that they meet approval of the end user.
Ensure that the entire installation is in compliance with 
all applicable national and local codes and ordinances 
having jurisdiction.
Secure all access panels (i.e. front cover and/or control 
box),  apply  power  to  the  unit,  then  start  the  unit,  and 
check for proper operation in each mode.  Instruct the 
owner  or  operator  regarding  the  unit’s  operation,  and 
the recommended routine maintenance schedule. 
NOTE: Maintaining a log for recording the dates of mainte-
nance  and/or  service  is  recommended,  and  should  be 
suggested to the owner or operator of the equipment.
Move  the  thermostat  switches  to  “OFF”  and  “AUTO”. 
This will keep the thermostat from cycling the chassis 
until final connections are complete.
Connect the duct work onto the 10” collar. Plastic wire 
ties  (field  supplied)  are  suggested  to  secure  the  duct 
work in place. Use 2 wire ties, one for each inner and 
outer flex duct sleeve.
Review the Final Installation Checklist before replacing 
the power quick disconnect, reconnecting power to the 
chassis or operating the chassis.
Present  the  owner  or  operator  of  the  equipment  with  the 
Installation  &  Operation  Manual,  all  accessory  installation 
instructions, and the name, address and telephone number 
of  the Authorized  Friedrich  Warranty  Service  Company  in 
the area for future reference if necessary. 
Chassis Operation 
Fresh Air Door 
Low Ambient Compressor Cut Out
Room Freeze Protection
The Fresh Air Door is an “intake” system. The fresh air door 
is opened via a slide on the front of the chassis located just 
above the indoor coil. Move the slide left to open and right to 
close the fresh air door. The system is capable of up to 60 
CFM of fresh air at .3  H20 internal static pressure.
Each chassis is equipped with low ambient protection in the 
form of a thermistor, which will prevent compressor opera-
tion at low suction temperature.
A.
B.
C.
This feature will monitor the indoor room conditions and in 
the event that the room falls below 40ºF the unit will cycle 
on high fan with the electric heater. This occurs regardless 
of mode.