The coil with the outside air flowing over it should be inspected
annually and cleaned as frequently as necessary to keep the
finned areas free of lint, hair and debris.
C
ONDENSER
, E
VAPORATOR
AND
  I
NDUCED
 D
RAFT
 M
OTORS
Bearings on the air circulating blower motor, condenser mo-
tor and the combustion fan motor are permanently lubricated.
No additional oiling is required.
L
UBRICATION
The fan shaft bearings, the 1 to 2 HP supply fan motors the
condenser fan motors and compressors are permanently lu-
bricated.
F
UNCTIONAL
 P
ARTS
Refer to the unit Parts Catalog for a list of functional parts.
Parts are available from your distributor.
SERVICE
WARNING
HIGH VOLTAGE! 
INSTALLATION
 
AND
 
REPAIR
 
OF
 
THIS
 
UNIT
 
SHOULD
 
BE
 
PERFORMED
 ONLY 
BY
 
INDIVIDUALS
 
MEETING
 
THE
 
REQUIREMENTS
 
OF
 
AN
 “E
NTRY
 L
EVEL
 T
ECHNICIAN
” 
AS
 
SPECIFIED
 
BY
 
THE
 A
IR
 C
ONDITIONING
 
AND
 
R
EFRIGERATION
 I
NSTITUTE
 (ARI). A
TTEMPTING
 
TO
 
INSTALL
 
OR
 
REPAIR
 
THIS
 
UNIT
 
WITHOUT
 
SUCH
 
BACKGROUND
 
MAY
 
RESULT
 
IN
 
PRODUCT
 
DAMAGE
PERSONAL
 
INJURY
 
OR
 
DEATH
.
THE FOLLOWING INFORMATION IS FOR USE BY QUALI-
FIED SERVICE AGENCY ONLY: OTHERS SHOULD NOT
ATTEMPT TO SERVICE THIS EQUIPMENT.
Common Causes of Unsatisfactory Operation of Heat Pump
on the Heating Cycle.
I
NADEQUATE
 A
IR
 V
OLUME
 T
HROUGH
 I
NDOOR
 C
OIL
When a heat pump is in the heating cycle, the indoor coil is
functioning as a condenser.  The return air filter must always
be clean, and sufficient air volume must pass through the
indoor coil to prevent excessive discharge pressure, and high
pressure cut out.
O
UTSIDE
 A
IR
 
INTO
 R
ETURN
 D
UCT
Do not introduce cold outside air into the return duct of a heat
pump installation.  Do not allow air entering the indoor coil to
drop below 65° F.  Air below this temperature will cause low
discharge pressure, thus low suction pressure, and exces-
sive defrost cycling resulting in low heating output.  It may
also cause false defrosting.
U
NDERCHARGE
An undercharged heat pump on the heating cycle will cause
low discharge pressure resulting in low suction pressure and
frost accumulation on the outdoor coil.
P
OOR
 “T
ERMINATING
” S
ENSOR
 
CONTACT
The unit’s defrost terminating sensor must make good ther-
mal contact with the outdoor coil tubing.  Poor contact may
not terminate the unit’s defrost cycle quickly enough to pre-
vent the unit from cutting out on high discharge pressure.