Toshiba RAV-SM802UT-E User Manual

Page of 196
– 110 –
12-1-3. Monitor Function of Remote Controller Switch
n
Call of sensor temperature display
<Contents>
Each sensor temperature of the remote controller, indoor unit, and outdoor unit can become known by calling
the service monitor mode from the remote controller.
<Procedure>
1
Push  
CL
 + 
TEST
 buttons simultaneously  for 4 seconds or more to call th e service monitor mode.
The service monitor goes on, the master indoor unit No. is displayed, and then temperature of the item
code
 
00 
 is displayed.
2
Push  th e temperature setup   / 
 buttons to select th e sensor No. (Item code) of th e sen-
sor to be monitored.
The sensor numbers are described below:
3
Th e temperature of indoor units and outdoor unit in a group control can be monitored by
push ing 
UNIT
 button to select th e indoor unit to be monitored.
4
Push ing 
TEST
 button returns th e display  to usual display .
*1 Only master unit in group control
1    2    3    4
<Operation procedure>
Returned to usual display
1
4
2
3   
ON / OFF
FAN
TEMP.
SWING/FIX
TIME
MODE
VENT
UNIT
SET
CL
FILTER
RESET TEST
TIMER SET
UNIT   No.
DATA
SET
R.C.
No.
Indoor
unit data
Item code
00
01
02
03
04
Data name
Room temp. (control temp.) *1
Room temp. (remote controller)
Room temp. (TA)
Heat exchanger temp. (TCJ)
Heat exchanger temp. (TC)
Outdoor
unit data
Item code
60
61
62
63
64
65
Data name
Heat exchanger temp. TE
Outside temp. TO
Discharge temp. TD
Suction temp. TS
Heat sink temp. THS