Toshiba RAV-SM802UT-E User Manual

Page of 196
– 35 –
Indoor unit
Outdoor unit
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
12.7mm
6.4mm
TCJ
sensor
Air heat exchanger
Strainer
Strainer
TC sensor
Packed valve
Outer dia. ØA
Packed valve 
Outer dia. ØB
Max.
50m
Min.
5m
TS sensor
Accumulator
(1500cc)
TD sensor
TO sensor
TE
sensor
4-way valve
(STF-0213Z)
Ø25 × L160
Rotary compressor
(DA220A2F-20L)
Heat exchangerØ8 
1 row 30 stages
FP1.3 flat fin
Capillary
Ø3×Ø2×
L530 
Ø25 × L210
Muffler
R410A 1.5 kg
Cooling
Heating
Ps
Pd
Modulating
(PMV)
(SKV-18D26)
Refrigerant pipe 
at gas side
Outer dia. ØA
Refrigerant pipe 
at liquid side
Outer dia. ØB
* The refrigerating cycle of the indoor units differs according to 
the models to be combined. For the refrigerating cycles of the 
other indoor units, refer to the corresponding Service Manuals 
described in the list on the cover.
RAV-SM562UT-E, RAV-SM562BT-E, RAV-SM562CT-E / RAV-SP562AT-E
*
4 poles are provided to this compressor.
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Revised : Nov. 2006
Standard
Cooling
Overload
Low load
Standard
Heating
Overload
Low load
Pressure
(MPa)
Pd
Ps
2.71
1.03
3.48
1.16
1.92
0.74
2.22
0.72
3.47
1.16
1.79
0.25
Pipe surface temperature (°C)
Discharge
(TD)
75
81
34
32
81
71
Suction
(TS)
  15
  20
    5
    6
  20
–16
Indoor heat
exchanger
(TC)
10
16
  2
38
55
30
Outdoor heat
exchanger
(TE)
  38
  51
  11
    2
  15
–18
Compressor
revolutions per
second (rps)
*
43
44
24
41
41
70
Indoor
fan
HIGH
HIGH
LOW
HIGH
LOW
HIGH
Indoor/Outdoor
temp. conditions
(DB/WB) (°C)
Indoor
Outdoor
27/19
35/–
32/24
43/–
18/15.5
–5/–
20/–
7/6
30/–
24/18
15/–
–15/(70%)