Toshiba RAV-SM802UT-E User Manual

Page of 196
– 48 –
RAV-SM1102AT-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect)
4-way valve solenoid coil
Compressor thermo. (Protection)
Coil (Pulse Motor Valve)
Type
ICF-280-100-R
DA420A3F-21M
CH-62
VHV-01AJ503C1
US-622
UKV-048E
Specifications
Output (Rated) 100 W
3 phase, 4P, 2000 W
6 mH, 18.5 A
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
50 k
Ω
 at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
AC 220 – 240 V
ON : 90 ± 5°C, OFF : 125 ± 4°C
RAV-SM802AT-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect))
4-way valve solenoid coil
Compressor thermo. (Protection)
Coil (Pulse Motor Valve)
Type
ICF-140-43-4R
DA150A1F-20F
CH-57
VHV-01AJ503C1
US-622
CAM-MD12TF-6
Specifications
Output (Rated) 43 W
3 phase, 4P, 1600 W
10 mH, 16 A
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
50 k
Ω
 at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C
6-2. Outdoor Unit
RAV-SM562AT-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect)
4-way valve solenoid coil
Compressor thermo. (Protection)
Coil (Pulse Motor Valve)
Type
ICF-140-43
DA150A1F-20F
CH-57
VHV-01AJ503C1
US-622
CAM-MD12TF-6
Specifications
Output (Rated) 43 W
3 phase, 4P, 1100 W
10 mH, 16A
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
10 k
Ω
 at 25°C
50 k
Ω
 at 25°C
T3.15 A, AC 250 V
25 A, AC 250 V
ON : 90 ± 5°C, OFF : 125 ± 4°C