– 93 –
NO
NO
YES
NO
YES
YES
* For RAV-SM562AT-E, replace control P.C. board.
Are connections of
cable/connector normal?
Are cablings of power and
current sensor normal?
Is not winding shorted?
(Is resistance between windings 0.6 to 1.2
W
?)
Is compressor normal?
Is not earthed?
Is not winding opened?
Compressor error 
®
 Replace
Compressor error 
®
 Replace
Compressor error 
®
 Replace
Check and correct circuit cables.
Check and correct circuit cabling 
such as cabling to compressor.
Check IPDU P.C. board.
Defect 
®
 Replace
Check IPDU.
Defect 
®
 Replace
* For RAV-SM562AT-E, replace control P.C. board.
YES
YES
NO
NO
NO
YES
[P29 error]
[H03 error]