Fluid Connections
1.
Connect a 1/4 npt(f) fluid hose from the fluid
source to the check valve (J) at the pump’s fluid
inlet manifold (K). The inlet dose valves (D, E)
will open and close alternately at the pump stroke
changeover, to maintain a steady flow into the
pump.
2.
Connect a 1/4 npt(f) fluid outlet hose from the
check valve (L) at the pump’s fluid outlet manifold
(H). The outlet dose valves (F, G) will open and
close alternately at the pump stroke changeover,
to maintain a steady flow out of the pump.
Figure 9 Fluid Connections
Electrical Connection
NOTICE
To avoid electrical component damage, remove all
system power before plugging any connectors.
Connect the cable from the pump control module in
the proportioner’s electrical control box to the cable
connector (N) on the pump motor (A).
The cable has two connectors, one for the motor
control and the other for encoder feedback. The
connectors are keyed differently to ensure correct
installation.