York GF9S*DH User Manual

Page of 40
268890-UIM-B-0607
6
Unitary Products Group
Downflow Air Conditioning Coil Cabinet
The Cooling Coil Cabinet can be used in place of the combustible floor
base for downflow installations on combustible materials. The furnace
should be installed with the cooling coil cabinet specifically intended for
downflow applications. The cooling coil cabinet must be secured to the
floor. A supply air duct plenum is installed through the opening pro-
vided. The supply air duct is then secured to the duct system with
screws and sealed to prevent leaks. If a matching cooling coil is used, it
may be placed directly on the furnace outlet using the accessory transi-
tion kit and sealed to prevent leakage. The transition kit must be used to
secure the cooling coil cabinet to the furnace casing when installed in a
downflow configuration.
These kits are required in downflow application when using G*F* series
coils. These kits are not required with MC/FC series coils, but please
ensurethat the coil and furnace are sucured and that there are noair
leaks.
This transition kit may be installed in one of two ways. The transition kit
may be installed and secured to either the furnace or the cooling coil
cabinet by the use of screws and then it must be sealed to prevent
leaks. 
If the transition kit has been installed on the cooling coil cabinet it
must be secured to the cooling coil cabinet with screws. The sup-
ply air side of the furnace is then placed on the cooling coil cabi-
net and then sealed for leaks.
If the transition kit has been installed on the supply air side of the
furnace it must be secured to the furnace with screws. The fur-
nace and the transition kit are then placed on the cooling coil cab-
inet and then sealed for leaks.
NOTE: Refer to instructions packed out with coil cabinet, for securing
and sealing to the furnace.
IMPORTANT: The furnace, transition kit, and the cooling coil cabinet
MUST BE SEALED as needed to prevent leaks, AND SECURED. Refer
to the assembly drawing in Figure 2.
IMPORTANT: On all installations without a coil, a removable access
panel is recommended in the outlet duct such that smoke or reflected
light would be observable inside the casing to indicate the presence of
leaks in the heat exchanger. This access cover shall be attached in
such a manner as to prevent leaks.
Horizontal Models
IMPORTANT: This furnace may be installed in a horizontal position on
either side as shown above. It must not be installed on its back.
Horizontal Installations With a Cooling Coil Cabinet
The furnace should be installed with the cooling coil cabinet specifically
intended for horizontal applications. If a matching cooling coil is used, it
may be placed directly on the supply air side of the furnace and sealed
to prevent leakage. A warm air duct plenum with 1" (2.54 cm) is
installed through the opening provided. The supply air duct system is
connected to the warm air plenum and sealed to prevent leaks.
IMPORTANT: The furnace, the cooling coil cabinet, and all duct work
MUST BE SEALED as needed to prevent leaks, AND SECURED. Refer
to the assembly drawing in Figure 2.
Attach the supply plenum to the air conditioning coil cabinet outlet duct
flanges through the use of S cleat material when a metal plenum is
used. The use of an approved flexible duct connector is recommended
on all installations. The connection to the furnace, air conditioning coil
cabinet and the supply plenum should be sealed to prevent air leakage. 
The sheet metal plenum should be crosshatched to eliminate any pop-
ping of the sheet metal when the indoor fan is energized. The minimum
plenum height is 12" (30.5 cm). If the plenum is shorter than 12" (30.5
cm) the turbulent air flow may cause the limit controls not to operate as
designed, or the limit controls may not operate at all. Also the plastic
drain pan in the under the air conditioning coil can overheat and melt
Refer to the installation instructions supplied with the air conditioning
coil for additional information.
Horizontal Installations Without a Cooling Coil Cabinet
When installing this appliance, the furnace must be installed so as to
create a closed duct system, the supply duct system must be con-
nected to the furnace outlet and the supply duct system must terminate
outside the space containing the furnace. When replacing an existing
furnace, if the existing plenum is not the same size as the new furnace
then the existing plenum must be removed and a new plenum installed
that is the proper size for the new furnace.
Attach the supply plenum to the furnace outlet duct flanges through the
use of S cleat material when a metal plenum is used. The use of an
approved flexible duct connector is recommended on all installations.
This connection should be sealed to prevent air leakage. The sheet
metal should be crosshatched to eliminate any popping of the sheet
metal when the indoor fan is energized. On all installations without a
coil, a removable access panel is recommended in the outlet duct such
that smoke or reflected light would be observable inside the casing to
indicate the presence of leaks in the heat exchanger. This access cover
shall be attached in such a manner as to prevent leaks.
 FIGURE 2:  Transition Kit Assembly
AIRFLOW
AIRFLOW
AIRFLOW
AIRFLOW
DOWNFLOW
FURNACE
TRANSITION
KIT
TRANSITION
KIT
COOLING
COIL
CABINET
REFRIGERANT
LINES
DRAIN
CONNECTIONS