York H*RD018 THRU 060 User Manual
254892-YTG-C-0606
10
Unitary Products Group
— = Not applicable.
1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED
H2RD018S06
AV24 2,5,8,10,15
17 –
600
18.0
11.7
14.00
11.50
H2RD024S06
AV24 2,5,8,10,15
17 –
800
23.2
16.5
14.00
11.50
H2RD030S06
AV36 5,8,10,15,18
21 –
1000
30.0
21.2
14.00
11.50
H2RD036S06
AV36 5,8,10,15,18
21 –
1200
35.2
25.0
14.00
11.50
AV/SV48 5,8,10,15,18,20,25
24
–
1200 35.8 25.0
13.75
11.00
H2RD042S06
AV/SV48 5,8,10,15,18,20,25
24
–
1400 40.5 29.1
14.00
11.50
H2RD048S06
AV/SV48 5,8,10,15,18,20,25
24
–
1600 47.0 34.7
13.50
11.00
H2RD060S06
AV/SV60 5,8,10,15,18,20,25
24
–
1800 55.0 39.1
13.15
11.00
1 & 3 PH 13 SEER AC WITH AHP / F*FP / F*FV
H2RD018S06
AHP18 2,5,8
17
–
650
17.7
12.3
13.00
11.00
AHP24 2,5,8,10
17 –
655
17.9
12.5
13.50
11.00
F*FP024 5,8,10
17 –
650
17.5
12.2
13.00
11.00
H2RD024S06
AHP24 2,5,8,10
17 –
830
23.0
16.8
13.00
11.00
AHP30 5,8,10
17
–
795
23.6
17.0
13.00
11.00
F*FP024 5,8,10
17 –
800
23.0
16.8
13.00
11.00
F*FP030 5,8,10,15
17 –
800
23.0
16.8
13.00
11.00
H2RD030S06
AHP30 5,8,10
17
–
1015
30.0
21.9
13.00
11.00
AHP36 5,8,10,15,18
17 –
1040
30.0
22.6
13.50
11.00
F*FP036 5,8,10,15,19
21
–
1000
29.6
21.3
13.00
11.00
H1RD030S(25,46)
AHP30 5,8,10
17
–
1015
29.7
21.7
13.00
11.00
AHP36 5,8,10,15,18
17 –
1040
29.7
22.4
13.50
11.00
F4FP036 5,8,10,15,19
21
–
1000
29.3 21.1
13.00
11.00
H2RD036S06
AHP36 5,8,10,15,18
17 –
1235
35.0
27.2
13.50
11.00
AHP42 5,8,10,15,18
21 –
1255
35.0
27.5
13.50
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1200 36.0
26.7 14.00
11.50
F*FP040 5,8,10,15
21 –
1200
34.8
25.4
13.00
11.00
H1RD036S(25,46)
AHP36 5,8,10,15,18
17 –
1235
34.7
27.0
13.50
11.00
AHP42 5,8,10,15,18
21 –
1255
34.7
27.3
13.50
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1200 35.7
26.5 14.00
11.50
F*FP040 5,8,10,15
24 –
1200
34.5
25.2
13.00
11.00
H2RD042S06
AHP42 5,8,10,15,18
21 –
1485
41.0
31.0
13.00
11.00
AHP/SHP48 5,8,10,15,20 24
–
1400
42.0 30.7
13.50
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1400 40.5
33.2 14.00
11.50
F*FP048 5,8,10,15
24 –
1400
41.0
31.0
13.00
11.00
H1RD042S(25,46)
AHP42 5,8,10,15,18
21 –
1485
40.0
30.3
13.00
11.00
AHP/SHP48 5,8,10,15,20 24
–
1400
41.0 30.0
13.50
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1400 39.5
32.5 14.00
11.50
F4FP048 5,8,10,15
24 –
1400
40.0
30.3
13.00
11.00
H2RD048S06
F*FV060 5,8,10,15,20,25
24
–
1600
47.5 36.9
13.50
11.00
AHP/SHP48 5,8,10,15,20 24
–
1675
47.0 36.8
13.00
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1600 47.0
36.2 13.75
11.00
H1RD048S(25,46)
AHP/SHP48 5,8,10,15,20 24
–
1675
46.0 36.1
13.00
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1600 46.0
35.5 13.75
11.00
H2RD060S06
F*FV060 5,8,10,15,20,25
24
–
1850
55.0 40.3
13.20
11.00
AHP/SHP60 5,8,10,15,20,25 24
–
1850 55.0
40.3 13.00
11.00
H1RD060S(25,46)
AHP/SHP60 5,8,10,15,20,25 24
–
1850 54.0
39.6 13.00
11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
2. Single phase units require single phase 2HK heaters.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC
HEAT KW
HEAT KW
2
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.