York H*RD018 THRU 060 User Manual

Page of 24
254892-YTG-C-0606
                            
10
Unitary Products Group
— = Not applicable.
1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED 
H2RD018S06
AV24 2,5,8,10,15 
17  –
600 
18.0 
11.7 
14.00 
11.50 
H2RD024S06
AV24 2,5,8,10,15 
17  –
800 
23.2 
16.5 
14.00 
11.50 
H2RD030S06
AV36 5,8,10,15,18 
21  –
1000 
30.0 
21.2 
14.00 
11.50 
H2RD036S06
AV36 5,8,10,15,18 
21  –
1200 
35.2 
25.0 
14.00 
11.50 
AV/SV48 5,8,10,15,18,20,25 
24 
1200 35.8  25.0 
13.75 
11.00 
H2RD042S06
AV/SV48 5,8,10,15,18,20,25 
24 
1400 40.5  29.1 
14.00 
11.50 
H2RD048S06
AV/SV48 5,8,10,15,18,20,25 
24 
1600 47.0  34.7 
13.50 
11.00 
H2RD060S06
AV/SV60 5,8,10,15,18,20,25 
24 
1800 55.0  39.1 
13.15 
11.00 
1 & 3 PH 13 SEER AC WITH AHP / F*FP / F*FV
H2RD018S06
AHP18 2,5,8 
17 
650 
17.7 
12.3 
13.00 
11.00 
AHP24 2,5,8,10 
17 –
655 
17.9 
12.5 
13.50 
11.00 
F*FP024 5,8,10 
17 –
650 
17.5 
12.2 
13.00 
11.00 
H2RD024S06
AHP24 2,5,8,10 
17 –
830 
23.0 
16.8 
13.00 
11.00 
AHP30 5,8,10 
17 
795 
23.6 
17.0 
13.00 
11.00 
F*FP024 5,8,10 
17 –
800 
23.0 
16.8 
13.00 
11.00 
F*FP030 5,8,10,15 
17  –
800 
23.0 
16.8 
13.00 
11.00 
H2RD030S06
AHP30 5,8,10 
17 
1015 
30.0 
21.9 
13.00 
11.00 
AHP36 5,8,10,15,18 
17  –
1040 
30.0 
22.6 
13.50 
11.00 
F*FP036 5,8,10,15,19 
21 
1000 
29.6 
21.3 
13.00 
11.00 
H1RD030S(25,46)
AHP30 5,8,10 
17 
1015 
29.7 
21.7 
13.00 
11.00 
AHP36 5,8,10,15,18 
17  –
1040 
29.7 
22.4 
13.50 
11.00 
F4FP036 5,8,10,15,19 
21 
1000 
29.3 21.1 
13.00 
11.00 
H2RD036S06
AHP36 5,8,10,15,18 
17  –
1235 
35.0 
27.2 
13.50 
11.00 
AHP42 5,8,10,15,18 
21  –
1255 
35.0 
27.5 
13.50 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1200  36.0 
26.7 14.00 
11.50 
F*FP040 5,8,10,15 
21  –
1200 
34.8 
25.4 
13.00 
11.00 
H1RD036S(25,46)
AHP36 5,8,10,15,18 
17  –
1235 
34.7 
27.0 
13.50 
11.00 
AHP42 5,8,10,15,18 
21  –
1255 
34.7 
27.3 
13.50 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1200  35.7 
26.5 14.00 
11.50 
F*FP040 5,8,10,15 
24  –
1200 
34.5 
25.2 
13.00 
11.00 
H2RD042S06
AHP42 5,8,10,15,18 
21  –
1485 
41.0 
31.0 
13.00 
11.00 
AHP/SHP48 5,8,10,15,20 24 
1400 
42.0  30.7 
13.50 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1400  40.5 
33.2 14.00 
11.50 
F*FP048 5,8,10,15 
24  –
1400 
41.0 
31.0 
13.00 
11.00 
H1RD042S(25,46)
AHP42 5,8,10,15,18 
21  –
1485 
40.0 
30.3 
13.00 
11.00 
AHP/SHP48 5,8,10,15,20 24 
1400 
41.0  30.0 
13.50 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1400  39.5 
32.5 14.00 
11.50 
F4FP048 5,8,10,15 
24  –
1400 
40.0 
30.3 
13.00 
11.00 
H2RD048S06
F*FV060 5,8,10,15,20,25 
24 
1600 
47.5  36.9 
13.50 
11.00 
AHP/SHP48 5,8,10,15,20 24 
1675 
47.0  36.8 
13.00 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1600  47.0 
36.2 13.75 
11.00 
H1RD048S(25,46)
AHP/SHP48 5,8,10,15,20 24 
1675 
46.0  36.1 
13.00 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1600  46.0 
35.5 13.75 
11.00 
H2RD060S06
F*FV060 5,8,10,15,20,25 
24 
1850 
55.0  40.3 
13.20 
11.00 
AHP/SHP60 5,8,10,15,20,25 24 
1850  55.0 
40.3 13.00 
11.00 
H1RD060S(25,46)
AHP/SHP60 5,8,10,15,20,25 24 
1850  54.0 
39.6 13.00 
11.00 
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. 
Cooling MBH based on 8
0°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters. 
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC 
HEAT KW
2
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.