York H*RD018 THRU 060 User Manual

Page of 24
254892-YTG-C-0606
                            
18
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the 
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
H2RD024S06
INDOOR COIL MODEL NO.
FC/MC/PC/UC24
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
75
T.C.
21.8
23.8
23.8
25.7
28.3
24.1
25.1
25.1
26.8
29.8
21.8
26.5
26.5
28.0
31.3
S.C.
21.8
19.5
15.2
16.6
13.6
24.1
23.0
17.6
19.1
15.6
20.4
26.4
19.9
21.6
17.5
KW
1.60
1.62
1.62
1.65
1.67
1.70
1.71
1.71
1.73
1.75
1.60
1.79
1.79
1.81
1.84
85
T.C.
20.4
21.9
21.9
24.2
26.4
21.4
23.6
23.6
25.3
27.7
22.5
25.3
25.3
26.3
29.0
S.C.
20.4
18.6
14.2
16.1
13.0
21.4
21.8
16.4
18.7
14.9
22.1
25.0
18.5
21.3
16.8
KW
1.71
1.72
1.72
1.77
1.79
1.77
1.82
1.82
1.85
1.88
1.83
1.91
1.91
1.94
1.97
95
T.C.
19.0
20.0
20.0
22.7
24.5
21.6
22.1
22.1
23.8
25.7
23.2
24.1
24.1
24.7
26.8
S.C.
18.7
17.6
13.3
15.5
12.3
21.2
20.6
15.2
16.6
14.2
23.2
23.6
17.1
21.0
16.0
KW
1.81
1.82
1.82
1.88
1.92
1.93
1.93
1.93
1.98
2.01
2.05
2.04
2.04
2.06
2.11
105
T.C.
17.6
18.1
18.1
21.2
22.6
20.8
20.5
20.5
22.1
23.6
23.9
22.9
22.9
23.1
24.6
S.C.
17.6
16.7
12.3
15.0
11.7
20.3
19.4
14.0
17.8
13.5
23.9
22.2
15.7
20.7
15.3
KW
1.92
1.92
1.92
2.00
2.04
2.09
2.04
2.04
2.09
2.14
2.27
2.16
2.16
2.19
2.25
115
T.C.
19.3
17.0
17.0
19.3
21.1
20.3
18.8
18.8
20.2
22.0
21.2
20.7
20.7
21.1
22.9
S.C.
19.3
16.0
11.7
14.2
11.2
20.3
18.2
12.8
16.8
13.1
21.2
20.5
14.0
19.4
14.9
KW
2.10
2.01
2.01
2.10
2.16
2.21
2.14
2.14
2.20
2.26
2.32
2.28
2.28
2.30
2.37
125
T.C.
15.4
15.8
15.8
17.4
19.6
17.0
17.2
17.2
18.3
20.4
18.5
18.5
18.5
19.2
21.2
S.C.
15.4
15.4
11.1
13.5
10.7
17.0
17.1
11.7
15.8
12.7
18.5
18.5
12.2
18.0
14.6
KW
2.09
2.09
2.09
2.19
2.28
2.24
2.24
2.24
2.30
2.39
2.37
2.39
2.39
2.41
2.49
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MA08B 
MC24B 
1.00 1.00 1.00 
MA08B 
MC30B 
1.00 1.00 1.00 
MA08B 
G*FD024H17 
1.00 1.00 1.00 
MA08B 
G*FD030H17 
1.00 1.00 1.00 
AHP24 
1.02 1.01 1.00 
AHP30 
1.02 1.02 1.03 
F*FP024 
1.02 1.01 1.00 
F*FP030 
1.02 1.01 1.00 
MV12B
FC/MC24B 
1.02 0.99 0.97 
MV12B
FC/MC30B 
1.02 0.99 0.97 
AV24
1.02 0.99 0.97 
FC/MC/PC/UC30 
1.00 1.00 1.00 
HC30 
1.02 1.02 1.02 
HD24 
1.03 1.04 1.02 
G*FA030S14 
1.00 1.00 1.00 
G*FA036S14 
1.00 1.00 1.00 
G*FA036S17,21 
1.00 1.00 1.00 
G*FD024H14,17 
1.00 1.00 1.00 
G*FD030H17 
1.00 1.00 1.00 
G*FD035H14 
1.00 1.00 1.00 
G*FD036H17 
1.00 1.00 1.00 
Variable Speed 
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC24A 
1.01 1.01 0.96 
PV9*A12
FC/MC/PC/24A 
1.01 1.01 0.97 
PV8*B16
FC/MC/PC/24B 
1.01 1.01 0.96 
P(C,V)9*B12
FC/MC/PC24B 
1.01 1.01 0.96 
PV8*A12
FC/MC/PC30A 
1.01 1.01 0.96 
PV9*A12
FC/MC/PC30A 
1.01 1.01 0.97 
PV8*B16
FC/MC/PC30B 
1.01 1.01 0.96 
P(C,V)9*B12
FC/MC/PC30B 
1.01 1.01 0.96 
PV8*A12
HC30 
1.02 1.03 0.98 
PV9*A12
HC30 
1.02 1.02 0.98 
PV8*A12
HD24 
1.04 1.04 0.99 
PV9*A12
HD24 
1.04 1.04 0.99