Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the 
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
*
= Single-phase outdoor units only.
*
= Single-phase outdoor units only.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
H2RD030S06 , H1RD030S(25,46) **
INDOOR COIL MODEL NO.
FC/MC/PC/UC30
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
800
1000
1200
ID 
DB 
(°F)
80 80
75
80
80
80 80 75
80
80 80 80
75 80 80
ID 
WB 
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 
65
T.C.
27.0 31.8 30.1 33.7 35.6 29.0 33.4 31.3 35.1 36.7 31.1 35.0 32.6 36.5 37.7 
S.C.
26.9 24.7 20.6 21.2 16.0 29.0 27.7 22.9 23.4 17.7 31.1 30.7 25.2 25.6 19.5 
KW
1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 
75
T.C.
25.9 30.3 28.7 32.1 33.6 27.9 31.9 29.9 33.4 34.5 29.8 33.5 31.1 34.7 35.4 
S.C.
25.9 24.2 20.0 20.5 15.6 27.8 27.0 22.3 22.7 17.2 29.8 29.8 24.5 24.9 18.8 
KW
1.9 1.9 1.9 2.0 2.0 1.9 1.9 1.9 2.0 2.0 2.0 1.9 2.0 2.0 2.0 
85
T.C.
24.9 28.8 27.2 30.4 31.7 26.7 30.4 28.4 31.7 32.4 28.6 32.0 29.6 32.9 33.1 
S.C.
24.9 23.7 19.5 19.7 15.2 26.7 26.3 21.7 21.9 16.7 28.5 28.9 23.9 24.1 18.1 
KW
2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.2 2.1 2.1 2.1 2.1 2.2 
95
T.C.
23.8 27.4 25.8 28.7 29.7 25.6 28.9 26.9 30.0 30.2 27.3 30.5 28.1 31.2 30.7 
S.C.
23.8 23.2 18.9 18.9 14.8 25.5 25.6 21.1 21.2 16.2 27.3 28.1 23.3 23.4 17.5 
KW
2.2 2.2 2.2 2.3 2.3 2.2 2.2 2.2 2.3 2.3 2.3 2.3 2.2 2.3 2.3 
105
T.C.
22.8 25.9 24.3 27.1 27.8 24.4 27.5 25.3 28.2 28.2 26.0 29.1 26.4 29.3 28.5 
S.C.
22.7 22.4 18.3 18.3 14.1 24.3 24.5 20.4 20.5 15.4 25.9 26.5 22.6 22.6 16.6 
KW
2.4 2.4 2.4 2.4 2.5 2.4 2.4 2.4 2.4 2.5 2.4 2.4 2.4 2.5 2.5 
115
T.C.
21.8 24.5 22.8 25.5 25.9 23.2 26.1 23.7 26.5 26.1 24.7 27.8 24.7 27.4 26.4 
S.C.
21.7 21.6 17.6 17.7 13.5 23.2 23.3 19.7 19.8 14.6 24.7 25.0 21.8 21.9 15.8 
KW
2.5 2.5 2.5 2.6 2.6 2.6 2.5 2.5 2.6 2.7 2.6 2.6 2.5 2.6 2.7 
125
T.C.
20.8 23.0 21.3 23.9 24.0 22.1 24.8 22.2 24.7 24.1 23.4 26.5 23.0 25.6 24.3 
S.C.
20.6 20.9 17.0 17.1 12.8 22.0 22.2 19.0 19.1 13.9 23.4 23.5 21.1 21.1 15.1 
KW
2.7 2.7 2.6 2.7 2.8 2.7 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.8 2.8 
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
**
For three-phase, decrease T.C. by 0.6 and S.C. by 0.3.
Air Handler
Coil
T.C.
S.C.
KW
MA12B 
MC30B 
1.00 1.00 1.00 
MA12B 
MC36B 
1.00 1.01 1.00 
MA12B 
G*FD036H17 
1.00 1.01 1.00 
AHP30 
1.01 1.04 1.01 
AHP36 
1.01 1.08 1.01 
F*FP036 
1.00 1.01 1.00 
MV12B*
FC/MC30B 
1.01 1.00 0.97 
MV12B*
FC/MC36B 
1.01 1.01 0.97 
MV16C*
FC/MC36C 
1.01 1.01 0.97 
AV36*
1.01 1.01 0.97 
FC/MC/PC/UC36 
1.00 1.01 1.00 
HC30 
1.00 1.03 1.00 
HC36 
1.01 1.04 1.01 
HD36 
1.01 1.05 1.01 
G*FA036S14 
1.00 1.00 1.00 
G*FD036H17 
1.00 1.00 1.00 
G*FD036H21 
1.00 1.00 1.00 
Variable Speed 
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC30A 1.01 
1.00 
1.01 
PV9*A12
FC/MC/PC30A 1.01 
1.02 
0.97 
PV8*B16
FC/MC/PC30B 1.01 
1.00 
1.01 
P(C,V)9*B12
FC/MC/PC30B 1.01 
1.00 
1.01 
PV8*A12
FC/MC/PC36A 1.01 
1.02 
1.01 
PV9*A12
FC/MC/PC36A 1.01 
1.03 
0.97 
PV8*B16
FC/MC/PC36B 1.01 
1.03 
0.97 
P(C,V)9*B12
FC/MC/PC36B 1.01 
1.03 
0.97 
PV8*C16
FC/MC/PC36C 1.01 
1.02 
1.01 
PV8*C20
FC/MC/PC36C 1.01 
1.02 
1.01 
P(C,V)9*C16
FC/MC/PC36C 1.01 
1.02 
0.97 
P(C,V)9*C20
FC/MC/PC36C 1.01 
1.02 
0.97 
PV8*A12
HC30 1.01 
1.03 
0.97 
PV9*A12
HC30 1.01 
1.03 
0.97 
PV8*B16
HC36 1.01 
1.05 
0.97 
P(C,V)9*B12
HC36 1.01 
1.05 
0.97 
PV8*A12
HD36 1.01 
1.05 
0.97 
PV8*B16
HD36 1.01 
1.06 
0.97 
PV8*C16
HD36 1.01 
1.06 
0.97 
PV8*C20
HD36 1.01 
1.06 
0.97 
PV9*A12
HD36 1.01 
1.05 
0.97 
P(C,V)9*B12
HD36 1.01 
1.06 
0.97 
P(C,V)9*C16
HD36 1.01 
1.06 
0.97 
P(C,V)9*C20
HD36 1.01 
1.06 
0.97