York AY012MA321 User Manual

Page of 16
246814-YTG-D-0606
12
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the 
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
AY018MA321
INDOOR COIL MODEL NO.
G2FD024S17
CONDENSER 
ENTERING AIR 
TEMPERATURE
ID CFM
450
600
750
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
16.3
18.5
18.6
20.3
22.1
17.8
19.1
19.1
20.8
22.5
19.3
19.7
19.7
21.2
22.9
S.C.
15.4
14.0
12.3
12.1
9.8
17.0
15.8
13.8
13.4
10.9
18.6
17.7
15.3
14.8
12.1
KW
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
75
T.C.
15.9
17.5
17.6
19.3
21.3
17.3
18.2
18.2
19.9
21.7
18.6
18.8
18.9
20.4
22.1
S.C.
15.0
13.4
11.7
11.6
9.5
16.5
15.3
13.3
13.1
10.6
17.9
17.2
14.9
14.6
11.8
KW
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
85
T.C.
15.6
16.6
16.6
18.3
20.5
16.7
17.2
17.3
18.9
20.9
17.9
17.9
18.1
19.6
21.2
S.C.
14.7
12.9
11.1
11.1
9.3
16.0
14.7
12.8
12.7
10.3
17.3
16.6
14.4
14.4
11.4
KW
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
95
T.C.
15.2
15.6
15.6
17.3
19.7
16.2
16.3
16.4
18.0
20.0
17.2
17.0
17.3
18.7
20.4
S.C.
14.3
12.3
10.5
10.6
9.1
15.5
14.2
12.3
12.4
10.0
16.6
16.1
14.0
14.2
11.0
KW
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
105
T.C.
13.9
14.6
14.7
16.3
18.6
15.1
15.3
15.4
17.0
18.9
16.3
15.9
16.1
17.6
19.3
S.C.
13.0
11.8
10.0
10.2
8.6
14.2
13.4
11.6
11.9
9.6
15.4
15.0
13.3
13.7
10.7
KW
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
115
T.C.
12.7
13.7
13.7
15.3
17.5
14.0
14.3
14.4
15.9
17.8
15.3
14.9
15.0
16.6
18.2
S.C.
11.8
11.2
9.5
9.7
8.2
13.0
12.5
11.1
11.4
9.2
14.3
13.8
12.6
13.2
10.3
KW
1.9
1.9
1.9
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
125
T.C.
11.4
12.8
12.8
14.4
16.4
12.9
13.3
13.3
14.9
16.7
14.4
13.9
13.8
15.5
17.1
S.C.
10.5
10.7
9.0
9.2
7.7
11.8
11.7
10.5
11.0
8.9
13.2
12.7
11.9
12.7
10.0
KW
2.1
2.1
2.1
2.2
2.2
2.1
2.1
2.1
2.2
2.2
2.2
2.2
2.2
2.2
2.2
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. 
Air Handler
Coil
T.C.
S.C.
KW
MV12B
FC/MC18B
1.02
1.03
0.94
MV12B
G4FD024H17T2A
1.02
1.03
0.94
AHP18
1.00
1.00
1.00
AHP24
1.00
1.00
1.00
F4FP024H06T2A
1.00
1.00
1.00
FC/MC/PC18
1.00
1.00
1.00
G4FA030S14T2A
1.00
1.00
1.00
G4FA036S17T2A
1.00
1.00
1.00
G4FA036S21T2A
1.00
1.00
1.00
G4FD024H14T2A
1.00
1.00
1.00
G4FD024H17T2A
1.00
1.00
1.00
G4FD030H17T2A
1.00
1.00
1.00
G4FD035H14T2A
1.00
1.00
1.00
HC24
1.00
1.00
1.00
UC18
1.00
1.00
1.00
Variable Speed 
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC18A
1.02
1.03
0.94
PV8*B16
FC/MC/PC18B
1.02
1.03
0.94
PV9*A12
FC/MC/PC18A
1.02
1.02
0.97
PV9*B12
FC/MC/PC18B
1.02
1.03
0.94
PV8*B16
G4FA036S17T2A
1.02
1.03
0.94
PV9*B12
G4FA036S17T2A
1.02
1.03
0.94
PV8*A12
G4FA030S14T2A
1.02
1.03
0.94
PV9*A12
G4FA030S14T2A
1.02
1.02
0.97
PV8*A12
G4FD024H14T2A
1.02
1.03
0.94
PV9*A12
G4FD024H14T2A
1.02
1.02
0.97
PV8*B16
G4FD024H17T2A
1.02
1.03
0.94
PV9*B12
G4FD024H17T2A
1.02
1.03
0.94
PV8*B16
G4FD030H17T2A
1.02
1.03
0.94
PV9*B12
G4FD030H17T2A
1.02
1.03
0.94
PV8*A12
G4FD035H14T2A
1.02
1.03
0.94
PV8*B16
FC/MC/PC18B
1.02
1.03
0.94
PV9*A12
FC/MC/PC18A
1.02
1.02
0.97