III. START-UP
CHECK EVAPORATOR FAN SPEED AND RECORD.                          
CHECK CONDENSER FAN SPEED AND RECORD.                          
AFTER AT LEAST 10 MINUTES RUNNING TIME, RECORD THE FOLLOWING MEASUREMENTS:
ELECTRICAL
SUPPLY FAN AMPS                           
EXHAUST FAN AMPS                           
ELECTRIC HEAT AMPS  L1                          
L2                          
L3                            (50 SERIES UNITS ONLY)
TEMPERATURES 
OUTDOOR-AIR TEMPERATURE
                         F 
DB (Dry-Bulb)
RETURN-AIR TEMPERATURE
                         F 
DB                          F   WB (Wet-Bulb)
COOLING SUPPLY AIR
                         F 
PRESSURES
GAS INLET PRESSURE                          IN. WG (48 SERIES UNITS ONLY)
GAS MANIFOLD PRESSURE STAGE NO. 1                          IN. WG 
STAGE NO. 2                          IN. WG (48 SERIES
UNITS ONLY)
REFRIGERANT SUCTION
CIRCUIT NO. 1                          PSIG 
CIRCUIT NO. 2                          PSIG
REFRIGERANT DISCHARGE CIRCUIT NO. 1                          PSIG 
CIRCUIT NO. 2                          PSIG
VERIFY REFRIGERANT CHARGE USING CHARGING CHARTS IN UNIT INSTALLATION INSTRUCTIONS
GENERAL
ECONOMIZER MINIMUM VENT SETTING TO JOB REQUIREMENTS
IV. NOTES
                                                                                                                                                                                                     
                                                                                                                                                                                                     
                                                                                                                                                                                                     
                                                                                                                                                                                                     
COMP A1
COMP A2
COMP B1
COMP B2
OIL PRESSURE
SUCTION PRESSURE
SUCTION LINE TEMP
DISCHARGE PRESSURE
DISCHARGE LINE TEMP
ENTERING CONDENSER AIR TEMP
LEAVING CONDENSER AIR TEMP
EVAP ENTERING AIR DB TEMP
EVAP ENTERING AIR WB TEMP
EVAP LEAVING AIR DB TEMP
EVAP LEAVING AIR WB TEMP
COMPRESSOR AMPS (L1)
COMPRESSOR AMPS (L2)
COMPRESSOR AMPS (L3)