NetworkAIR ACPA4000
Clean the condenser filter and test the LCDI plug
The condenser filter traps large items that may fall into the ducts. Periodically check and clean the filter 
to prevent damage to the condenser. While power is off, test the LCDI plug for proper operation.
1. Turn off the equipment and unplug it from its 
electrical outlet.
2. Remove the condenser air intake duct from the back 
of the equipment.
3. Clean the filter (inside the air intake duct) using your 
hand or a dry cloth. 
4. Press the TEST button on the LCDI plug. The 
POWER LED should go off.
5. Press the RESET button on the LCDI plug. The 
POWER LED should come on.
Clean the cabinet
Turn off the equipment and unplug it from its electrical outlet. Use a moist rag to wipe down the cabinet.
Caution: Do not clean the surface with thinners, alcohol, polishing powder, alkaline 
detergent, acid, or an abrasive brush. Using these items will damage the cabinet.
Update the main control board firmware
Occasionally, new firmware becomes available which may add new features. Firmware is available for 
download through the APC software/firmware downloads page, www.apc.com/tools/dowload
You will need a computer with a serial port, a null modem serial cable, and a terminal emulation program 
that can use the xmodem protocol.
na03
11
a
Caution: To avoid equipment damage, do 
not test the LCDI plug while the equipment 
is operating.
na24
72
a
RESET button
TEST button