SPECIFICATIONS FOR LX-85 BOILER
Fuel Rate Input:
85,000 BTUH maximum
25,000 BTUH minimum
Boiler Water Volume:
.75 gallon (6.25 lbs)
Water Piping Connections:
1" NPT (male)
Gas Piping Connection:
1/2" NPT (female)
Vent Connection:
3" nominal I.D. pipe (PVC, CPVC or stainless steel)
Air Intake Connection:
3" nominal I.D. pipe (PVC, CPVC or stainless steel)
Weight of Boiler (uncrated):
105 lbs.
Gas orifice size:
Natural Gas - No orifice used *
Propane - 0.190" diameter 
**
*Note: No orifice changes are required for high altitude installations.