STARTING THE APPLIANCE
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32
8 716 113 389b (09/07) 
31
C
O
MMI
S
S
IO
N
IN
G
F
H
G
Return
Flow
TANK
A
B
C
A
B
C
A -  Bleed & pressure gauge port
B -  Pressure adjustment
C -  Vacuum gauge port
D -  Retaining screws - cover
D
D
DANFOSS
BFP 11 L3 OIL PUMP
SUNTEC
AS47C OIL PUMP
BURNER LOCKOUT 
C
B
A
D
RIELLO
RDB OIL PUMP
BURNER LOCKOUT RESET 
BUTTON (D) FOR
25/32 MODEL
GREENSTAR HEATSLAVE EXTERNAL 
max
flue
reset
boiler
reset
max
lockout
on
service
1
BURNER LOCKOUT RESET 
BUTTON (D) FOR 12/18 
& 18/25 MODELS
(Under control box)
(On top of burner control box)
E - Lockout indicator
STARTING THE APPLIANCE
IMPORTANT: Never run the appliance when
the appliance/system is unpressurised
(sealed systems) or empty.
1
Check the oil supply is correctly fitted and
in good working order before turning on
the oil supply valves to the boiler.
Turn on the main oil supply valve at the tank
and draw off at least 2
1
/
2
litres of oil until a 
steady flow of clear uncontaminated oil can
be seen as follows:
•  The oil supply to the boiler should be
primed before the burner is operated to
avoid unnecessary pump wear.
•  The use of an oil suction pump will prime
and flush through any oil supply set up 
simply and easily, alternatively the 
following procedures can be used.
Single pipe gravity feed systems:
Disconnect the flexible oil hose and open
the isolating valve to discharge the oil into a
suitable container.
If a top entry tank has been used the 
pipework will need to be primed before the
oil will discharge under gravity.
When completed, close the isolating valve,
reconnect the flexible oil hose.
Double pipe sub-gravity feed systems 
and single pipe suction lift with de-aerator:
To prime a de-aerator, disconnect the      
flexible oil inlet hose (F) from the isolation valve
and place in a container of kerosene (G). 
Connect a spare flexible oil hose (H), to
discharge into container (G). Open the
isolating valve, turn on the power to the boiler 
and set the programmer to ON. Prime the 
de-aerator until there is a steady flow of oil into
container (G). Turn off the boiler then 
reconnect the flexible oil inlet hose (F).
Turn on the boiler, the oil level in the 
de-aerator will drop as the oil is used until 
the oil is drawn from the tank. If the 
de-aerator empties and the burner locks out 
before the oil is drawn from the tank, prime 
the de-aerator again.
Open the isolating valve and the oil pump
bleed valve (A) to discharge into a suitable
container once the boiler is started up.
Switch on the electricity supply to the boiler.
Set the programmer to ON for CH and DHW.
Turn on the boiler CH control thermostat.
Allow the burner to run through to lockout
indicated by the illumination of the lockout
indicator (E).
Wait 2 minutes then press the lockout reset
button (D).
Repeat the procedure at least 3 times or until a 
steady stream of oil, without air, runs from the 
bleed port, then relock the bleed port (A).
Switch off the boiler.
Remove the oil pump filter, clean with 
kerosene and refit.
The internal filter is accessed by removing 
the oil pump cover on the Danfoss BFP 11 
L3, Suntec AS47C and Riello RDB.
Safely dispose of the container/discharge.