Emerson 16C26S-010 User Manual
11
TECHNICAL REPAIR GUIDE
All voltage measurements indicated can be made with a
high voltage D.C. probe and a general purpose volt ohm
meter. For example: Simpson 260 or equivalent.
high voltage D.C. probe and a general purpose volt ohm
meter. For example: Simpson 260 or equivalent.
NOTE: All tests to be performed with the Ozone Reduc-
tion Jumper intact.
tion Jumper intact.
NOTE: When servicing the power pack components, all
wiring must be routed to factory specifications.
wiring must be routed to factory specifications.
WARNING
!
Do not attempt repair of this unit unless you are
familiar with the necessary tools, equipment, util-
ity connections and potential hazards.
familiar with the necessary tools, equipment, util-
ity connections and potential hazards.
Repair should be performed only by a qualified
service provider.
service provider.
Failure to do so could result in reduced perfor-
mance of the unit, serious personal injury or
death.
mance of the unit, serious personal injury or
death.
This guide contains service checks to assist service
personnel in locating and correcting any malfunction that
might occur to render the air cleaner ineffective or inop-
erative. The air cleaner has been designed with replace-
able components, such as the high-voltage power supply.
This allows the serviceman to replace a faulty component
rather than attempt repairs of such components in the
field.
personnel in locating and correcting any malfunction that
might occur to render the air cleaner ineffective or inop-
erative. The air cleaner has been designed with replace-
able components, such as the high-voltage power supply.
This allows the serviceman to replace a faulty component
rather than attempt repairs of such components in the
field.
The solid-state power supply is not
designed for individual component part
replacement and must be replaced as
a complete "snap-in" unit.
designed for individual component part
replacement and must be replaced as
a complete "snap-in" unit.
Input voltage: 120 VAC 50/60 Hz.
Output to light: 1.5 to 2.5 VDC
H.V. Output: 6450 VDC (nom)
Output to light: 1.5 to 2.5 VDC
H.V. Output: 6450 VDC (nom)
Collecting Cell
Specifications
Power Supply
Specifications
1600 cfm - 1.5 Ma @ 6450 VDC
Operating
Light
Light
Power
Supply
Supply
Cell Contact
& Insulator
& Insulator
ON/OFF
Switch
Switch
Cover Assembly
Power Pack
Assembly
Assembly
L1
120 VAC
Connector
Connector
Wht
Wht
Gnd
Red
Blk
Blk
Blu
L2
Figure 23