Jotul Wood Stove User Manual

Page of 28
7
Stove clearances
Unprotected surfaces
Protected surfaces (NFPA 211)
Top vent/vertical
Side
Rear
Corner
Side
Rear
Corner
Single wall pipe
21"
13.5"
13"
13"
11"
9"
W/out rear heatshield
535mm
345mm
330mm
330mm
280mm
230mm
Single wall pipe
21"
11"
11"
13"
11"
9"
With rear heatshield
535mm
280mm
280mm
330mm
280mm
230mm
Shielded single wall pipe
21"
9"
9"
13"
8"
8"
With rear heatshield
535mm
230mm
230mm
330mm
205mm
205mm
Double wall pipe
24"
9"
9"
13"
8"
8"
With rear heatshield
610mm
230mm
230mm
300mm
205mm
205mm
Double wall pipe
24"
15"
15"
12"
8"
8"
W/out rear heatshield
610mm
380mm
380mm
305mm
205mm
205mm
Connector
Unprotected surface
Protected surface (NFPA 211)
clearances (pipe)
Vertical installation
Vertical installation
Single wall pipe
18"
6"
460mm
150mm
Double wall pipe
pipe mfgr.listing
pipe mfgr.listing
Connector
Unprotected surface
Protected surface (NFPA 211)
clearances (pipe)
Horizontal installation
Horizontal installation
Single wall pipe
18"
9"
460mm
230mm
Double wall pipe
pipe mfgr.listing
pipe mfgr.listing
Very Important:
Top vent/vertical - assumes the connector pipe is exiting off the top of the stove and traveling vertically. If top vented
to any horizontal runs - the stove’s position is dictated by the connector pipe clearances.
Rear vent/horizontal - assumes the connector pipe exits from the rear of the stove and runs horizontally to the
chimney. If rear vented to vertical run - the stove position is dictated by the connector pipe clearances.
Minimum alcove dimensions:
Unprotected surface
Protected surface (NFPA 211)
Vertical venting.
Vertical  venting
Assumes top exit:
Assumes top exit:
Minimum alcove width
55” (1400mm)
41” (1040 mm)
Maximum alcove depth
48” (1220mm)
48” (1220 mm)
Height above the top of the stove
71” (1805mm)
71” (1805 mm)
Jøtul F 602 Woodstove Clearances
USA