Regency Freestanding Woodstove
8
 
Unit 
 
       From Unit                            From Corner                       From Flue Center-Line
 
 
 
          B 
               C                    D 
              F
Medium F2400M 
with Airmate                  15" (381 mm)     5.5" (139 mm)     4" (101 mm)   27" (685 mm)    12" (304 mm)    15.5"  (393 mm)
 
 
with Rear Defl ector       15" (381 mm)   6.5" (165 mm)     6" (152 mm)   27" (685 mm)    13" (330 mm)    17.5" (444 mm)
Medium S2400M Step Stove                        15" (381 mm)   5.5" (139 mm)     4" (101 mm)   27" (685 mm)    12" (304 mm)    15.5" (393 mm)
Residential Installation “C” Vent  (Single Wall)
 
Unit 
 
       From Unit                           From Corner                        From Flue Center-Line
 
 
 
    A 
        B 
           C 
               D                     E 
           F
 
Medium F2400M 
with Airmate                16" (406 mm) 
11" (279 mm)   6" (152 mm)     28" (710 mm)    17.5" (444 mm)    17.5" (444 mm)
 
 
with Rear Defl ector     18" (457 mm) 
12" (304 mm)   6.5" (165 mm)  30" (762 mm)    18.5" (469 mm)    19.5" (495 mm)
Medium S2400M Step Stove                     16" (406 mm) 
11" (279 mm)   6" (152 mm)     28" (710 mm)    17.5" (444 mm)    17.5" (444 mm)
Residential  Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling 
level.
INSTALLATION
 
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)   
 
Unit 
 
       From Unit                                    From Corner                   From Flue Center-Line 
 
 
 
                  C 
       E 
                  F
Medium F2400M
 
             with Airmate                              15" (381 mm)       5.5" (139 mm)     4" (101 mm)   27" (685 mm)   12" (304 mm)    15.5"  (393 mm)
 
             with Rear Defl ector                   15" (381 mm)      6.5" (165 mm)     6" (152 mm)   27" (685 mm)   13" (330 mm)    17.5" (444 mm)
Medium S2400M Step Stove                         15" (381 mm)      5.5" (139 mm)     4" (101 mm)   27" (685 mm)    12" (304 mm)    15.5" (393 mm)
ROOM AIR 
IMPORTANT
For installation using room air for combustion, 
remove knockout from the pedestal, and/or from 
the bottom if using a heat shield.
Mobile home installations require the use of 
outside air.
MINIMUM CLEARANCE TO 
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the 
rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, 
and from the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
On pedestal units there are two locations where 
outside air may be adapted to the unit. If us-
ing the bottom of the pedestal, do not remove 
knockout from the rear of the pedestal. Only 
remove rear knockout if outside air will be 
brought in from the rear.
On leg units outside air can only be brought in 
from the bottom of the heat shield.
Note:  Once the knockout is removed there 
are two tabs remaining. Bend both 
tabs out for ease of installation when 
attaching outside air.