Regency Wraps U38-LP1 User Manual

Page of 32
Regency
®
 U38-1 ULTIMATE Freestanding Gas Stove
13
LOG SET 
INSTALLATION
Read the instructions below carefully and 
refer to the diagrams.  If logs are broken 
do not use the unit until they are replaced. 
Broken logs can  interfere with the pilot 
operation.
The gas log kit contains the following:
a) 02-65  Rear 
Log 
b)  02-56  Middle Left Log 
c)  02-44  Front Left Log 
d) 02-46  Left 
Top 
Log 
e)  02-45  Front Right Log 
f) 02-47 Center 
Log 
g) 02-48  Middle 
Right 
Log 
h)    Embers 
 
902-151
i)    Lava 
 
902-154
 
Embers.
Embers
The "02" refer numbers (i.e. 02-65) are 
molded into the rear of each log.
1)  Carefully remove the logs from the box and 
unwrap them.  The logs are fragile, handle 
with care - do not force into position.
2)  Sprinkle the embers on the left and right 
sides of the fi rebox base. 
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 730-920  
Contains:
Qty. Part # 
Description
1  904-240  Burner Orifi ce #37 (NG)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033 Instruction 
Sheet
Propane Conversion Kit 730-922
Contains:
Qty. Part # 
Description
1  904-390  Burner Orifi ce #52 (Propane)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033 Instruction 
Sheet
1)  Shut off the gas supply.
2)  Open the front door.  Carefully remove the 
logs and lava rock.
3)  Remove burner. See diagram below.
Burner Orifi ce
Note: Use a 
magnetic type 
screwdriver if possible.
Move Rear Log 
Pins forward to 
front holes.
Vent Restrictor setting at High 40,000 Btu/h
Vent Restrictor setting at Low  30,000 Btu/h
INSTALLATION
4)  Unscrew the 2 Rear 
Log Pins and move 
to the front hole 
position.
5)  Remove Rear Log 
Bracket and slide 
the Log Bracket 
Restrictor between 
the Rear Log Brack-
et and the burner, 
secure with the 2 
screws.
7)  Reinstall new burner orifi ce (NG stamped 
#37 or LP stamped #52) and tighten.
8)  Reverse steps 3) and 2).
9)  Adjust Vent restrictor setting: To set the Vent 
restriction as indicated in the diagram, simply 
loosen the screws and push the vent restric-
tor plate to the correct position. Tighten the 
screws.
 
 
 Unit  Btu/h 
Restrictor 
Opening
 U38-1 
40,000  A 
1-3/8" 
(35mm)
 U38-1 
30,000  B 
1-1/8" 
(29mm)
6)  Remove burner orifi ce  with a 1/2" wrench 
and discard.
10) Attach the label  "This unit has been con-
verted to..." on top of the Serial # decal over 
the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of fl ame control.  Check 
for proper fl ame appearance and glow on