Regency Wraps U38-LP1 User Manual

Page of 32
Regency
®
 U38-1 ULTIMATE Freestanding Gas Stove
7
Side View 
Rear View
Outside Air Through 
Rear of Pedestal
Remove the blanking plate from the rear of the 
pedestal cover plate and bend the two tabs 
out 90 degrees. Pipe fresh air into the pedestal 
area by using duct pipe with a mesh grill at the 
outside termination. Attach the pipe to the tabs 
with screws.
OPTIONAL 
OUTSIDE AIR
Outside air for combustion can be brought in 
either through the bottom of the pedestal or 
through the rear plate of the pedestal. 
For both bottom and rear "outside air" the Ped-
estal Cover Plate must be installed. Loosen the 4 
screws on the rear of the pedestal and slide the 
cover plate over them. Slide the plate to the left 
to center it and tighten down the 4 screws.
Outside Air Through 
Pedestal Bottom
Once you have properly marked the position of 
your unit as outlined in "General Information" 
and "Clearances to Combustibles", cut a prop-
erly sized hole though the fl oor directly under 
your pedestal base to the outside.  Pipe fresh 
air into the pedestal area by using appropriate 
metallic duct pipe with a mesh grill at the outside 
termination. Do not remove the knockout.
INSTALLATION
CLEARANCES TO 
COMBUSTIBLES
The clearances listed below are MINIMUM 
distances.  Measure the clearance to both the 
appliance and the chimney connector.  (The 
farthest distance is correct if the two clear-
ances do not coincide.) 
For example, if the 
appliance is set as indicated in one of the fi gures 
but the connector is too close, move the stove 
until the correct clearance to the connector is 
obtained.  
This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting  or vinyl when 
the bottom pedestal cover plate (provided with 
unit) is installed.
This appliance may be installed only with the 
clearances as shown in the situations pictured.  
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances. 
Use the minimum clearances shown in the dia-
grams below for installation with "B" vent.
Minimum ceiling height is 36" / 914 mm from 
top of unit.
6)  Test Gas Pressure.  Refer to the "Gas Pipe 
Pressure Testing" section.
7)  Install standard and optional features. 
 
Refer to the following sections where 
applicable.
 
a. Log Set Installation
 b. 
Front 
Door 
Installation
 
c. Louver Installation
 d. 
Wall 
Thermostat
 e. 
Remote 
Control
8)  Test for fl ue spillage (draft test).  Refer to 
the "Test for Flue Spillage" section.
9)  Final check. Refer to the "Final Check" 
section.
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained to 
customer.
This includes:
1)
  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to 
ensure that the fl ame does not carbon. 
First allow the unit to burn for 15-20 min. 
to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning or that results in 
damage is not the responsibility of the manu-
facturer.
U38-NG1 & U38-LP1 REFERENCE 
DIMENSIONS
C  Back Wall to Flue Centerline 10-3/4" / 273 mm
D  Side Wall to Flue Centerline  20-1/2" / 520 mm
F  Side Wall to Flue Centerline  11" / 280 mm
U38-NG1 & U38-LP1 Clearances
A  Side Wall to Unit 
7-1/2" / 190 mm
B  Back Wall to Unit 
6" / 155 mm
E  Side Wall to Unit 
2" / 50 mm
If further reduced clearances are needed, obtain 
requirements for construction of a protected wall 
from your local building authorities and their al-
lowable reductions of the listes clearances.