 ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove
9
PLANNING YOUR VENTING INSTALLATION
INSTALLATION
 IMPORTANT
Read  all instructions carefully before starting 
the installation. Failure to follow these instruc-
tions may create a fi re or other safety hazard, 
and will void the warranty. Be sure to check the 
venting and clearance to combustible require-
ments in "Clearances to Combustibles" to "Rigid 
Pipe Venting - Vertical Termination" sections. 
Consult your local building codes before begin-
ning installation.
The location of the termination cap must con-
form to the requirements in the" Exterior Vent 
Terminal Locations" section.
VENTING 
INSTALLATION 
PRECAUTIONS
The Regency
®
 Direct Vent System and the 
Vertical Termination with the Co-linear Flex 
System are  engineered products that have 
been designed and tested for use with the 
U37-NG1, and U37-LP1. The Regency
®
 war-
ranty will be voided and serious fi re, health or 
other safety hazards may result from any of the 
following actions:
1)  Installation of any damaged Direct Vent 
component
2) Unauthorized 
modifi cation of the Direct Vent 
System
3)  Installation of any component part not 
manufactured or approved by Regency
®
  
Industries Ltd.
4)  Installation other than as instructed by 
Regency
®
 Industries Ltd.
Warning: Always maintain required 
clearances (air spaces) to nearby com-
bustibles to prevent a fi re hazard. Do 
not fi ll air spaces with insulation.
The minimum clearance requirements between 
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check 
the vent termination clearance requirements 
from decks, windows, soffi ts, gas regulators, air 
supply inlets and public walkways as specifi ed 
in the "Exterior Vent Terminal Locations" section 
and in your local building codes.
The gas appliance and vent system 
must be vented directly to the outside 
of the building, and never be attached 
to a chimney serving a separate solid 
fuel or gas-burning appliance.
Each direct vent gas appliance must use its own 
separate vent system. Common vent systems 
are prohibited.
SAFETY PRECAUTIONS 
FOR THE INSTALLER
1)  Wear gloves and safety glasses for protec-
tion.
2)  Exercise extreme caution when using lad-
ders or on roof tops.
3)  Be aware of electrical wiring locations in 
walls and ceilings.
See the "Exterior Vent Terminal Locations" 
section for the requirements. 
.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe 
for your particular requirements. Determine the 
minimum clearance to combustibles from the 
rear of the unit to the wall. It is also important to 
note the wall thickness. Before cutting the vent 
hole through the wall ensure that ALL vent and 
termination clearances (see the "Exterior Vent 
Terminal Locations" section) will be met.
*If this is an outside corner, the minimum distance between the vent and the outside corner 
is 12" (30cm). See "F" on the diagram in the "Exterior Vent Terminal Locations" section.
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
For corner installation, Restrictor must 
be set at 1-1/4" open.
For straight rear installation, Restrictor 
must be set at 1-1/8" open.