F.  Convection Blower Replacement
Figure 36.1
Figure 36.3
epress a  and 
Snap t 
Po er 
S ppl
Remove 
Left Side
Panel
Disconnect Wire Harness 
from Bottom of Blower
Remove  
Screws
Remove 
Right Side
Panel
Figure 36.2
1.  Follow the proper shut down procedures as outlined on 
page 30, Section 10.A.
2.  Remove the left and right side panels by removing the 4 
screws using a Phillips head screw driver.  Figure 36.1.
3.  Depress the tab on the left side and snap out the power 
supply.  You do not need to disconnect any wires.  
Figure 36.1.
4.  Remove the 2 screws at the bottom of the back panel so 
there will be room to remove the blower.  Figure 36.1
5.  Reach behind the blower and release the latch by push-
ing the top of the latch towards the blower.  Figure 36.2.
6.  Rock the top of the blower slightly and lift up.  The 
blower will pass around the control board and out the 
left side of the appliance.
7.  Disconnect the wire harness from the bottom of the 
blower by depressing the tabs on the sides of the con-
nector and then pulling to remove.  Figure 36.1.
8.  Re-connect wire harness to the new blower.
9.  Install replacement blower by placing the bottom flange 
into the opening first then rotate blower up into posi-
tion.  
10. When the blower is properly positioned the latch will engage 
the notch to hold the blower in place.  Figure 36.3.
11.   Re-secure the back panel, snap the power supply back 
in and re-secure the side panel(s).
ot h
Lat h
Lat h ngaged