Regency FG37-NG User Manual

Page of 32
6
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
INSTALLATION
CHECKLIST
1) Check Clearances to Combustibles (page
6),    location  of  unit  (page  6)  and  fluing
requirements  (pages  6-9).
2) Install fluing: Check all fluing requirements,
pages  8-12.
3) Make gas connections, page 12. Test the
pilot. Must be as per diagram, pages 15  &
22.
4) If necessary, convert from NG to LPG (page
13).
5) Install log set, page 15.
6) Install Front Door Front, page 16.
7) Test Gas Pressure, page 17.
8) Install Louvres, page 17.
9) Install optional Remote Control, page 18.
10) Final check, page 18.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly  and  operation  fully  explained  to
customer.
This  includes:
1) Clocking the appliance to ensure the cor-
rect  firing  rate  (rate  noted  on  label)  after
burning appliance for 15 minutes.
2) If  required,  adjusting  the  primary  air  to
ensure that the flame does not carbon. First
allow  the  unit  to  burn  for  15-20  min.  to
stabilize.
CAUTION:  Any  alteration  to  the  product
that  causes  sooting  or  carboning  that
results  in  damage  is  not  the  responsibil-
ity  of  the  manufacturer.
LOCATING  YOUR
REGENCY  GAS  STOVE
When selecting a location for your stove, en-
sure that the clearances listed above are met as
well as ensuring that there is adequate acces-
sibility for servicing and proper operation.
For Flu Termination requirements, see page 7.
This appliance is Listed for bedroom  installa-
tions when used with a Listed Millivolt Thermo-
stat.  Some  areas  may  have  further  require-
ments, check local codes before installation.
This appliance is Listed for Alcove installations,
maintain  minimum  Alcove  clearances  as  fol-
lows, minimum ceiling height of 1.7m,  minimum
width of 1.0m and a maximum depth of  0.9m.
INSTALLATION
Use  the  minimum  clearances  shown  in  the
diagrams  below:
FG37-NG & FG37-LPG Clearances
A Side Wall to Unit
190 mm
B Back Wall to Unit
76 mm
E Side Wall to Unit
114 mm
FG37-NG & FG37-LPG
Reference  Dimensions
C Floor to Flue Centerline
635 mm
D Side Wall to Flue Centerline 521 mm
A) Cross  Corner
B) Flush  with  Wall/Alcove
C) Flat on Wall Corner
D) Flat on Wall
CLEARANCES  TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure  the  clearance  to  both  the  appliance
and  the  chimney  connector.  The  farthest
distance  is  correct  if  the  two  clearances
do not coincide. For example, if the appliance
is set as indicated in one of the diagrams but the
connector is too close, move the stove until the
correct clearance to the connector is obtained.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type
of  installation  with  another  in  order  to
achieve  closer  clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with unit)
is installed.
COMBUSTION  AND
VENTILATION AIR
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra  provision  for  combustion  air  inside
the  room  is  not  required.
Minimum ceiling height
is  914 mm from top of
unit.