Procom QL300RYLA-W User Manual

Page of 25
  1 6
TROUBLESHOOTING
REMEDY
     WARNING
:Make sure that power
is turn off before proceeding....
       WARNING:
  
Turn off  and let cool
before servicing. Only a  qualified
service  person  should service and
repair  fireplace.
       CAUTION: Never use a wire,
needle, or similar object  to clean
ODS/pilot. This  can  damage  ODS/
pilot  unit.
When   pressing the button of ignitor
button  is  pressed, there  is   spark at
ODS/pilot but  no  ignition
OBSERVED  PROBLEM
POSSIBLE CAUSE
1.   Gas   supply   turned   off   or   equip-
ment shut off  valve closed
2.  Air in gas lines when installed.
3.   Depleted gas supply
4.  ODS/pilot  is  clogged
5.   Gas regulator setting is not correct
6.  Pilot electrude position is not
correct
7. Wire is not correct or loosen
8 Gas valve is damage
1.  Turn on gas  supply  or  open
 equipment shutoff valve
2
.
3. Contact    local    propane/LP   gas
  company
4    Clean    ODS/pilot (see   Cleaning
and
       Maintenance,page 13 ) or replace
      ODS/pilot  assembly
5.   
   Replace  gas  control
6.   Replace Pilot
7.   Check the wine and make wine
correct.
8.   Replace gas valve
No spark when press in ignition button
1. No power to heater
2. No battery in transmitter or battery
isn’t correctly assembly
1. Check the electric power
2. Place or replace the battery.
1.  Thermocouple  connection  loose
at  control  board
2.    Pilot  flame  not  touching
thermcouple  which  allows thermo-
couple  to  cool,   causing  pilot
flame  to  go  out.  This  problem
could  be  caused  by  one or  both of
the following
       A)   Low  gas  pressure
       B)  Dirty  or  partially  clogged
ODS/ pilot
3.   Thermocouple  damaged
4.   Control  valve  damaged
1.  Hand tighten until snug, then
tighten 1/4  turn more.
2.  A) Contact local propane/LP gas
company.
     B)  Clean ODS/pilot (
see Cleaning
and Maintenance
, page 13) or
replace
ODS/pilot  assembly
3.    Replace  thermocouple
4.    Replace  control  valve
Burner does not light after  ODS/pilot
is  lit
1.    Burner orifice clogged
2.   Inlet  gas  pressure  is  too  low
3.   Burner  orifice  diameter  is  too
small
4.   Thermocouple  leads  discon-
nected  or improperly connected
5.   Burners  will  not  come  in
remote position
1.Clean burner (
see Cleaning
      and   Maintenance
, page 13) or
replace  burner orifice.
2.  Contact    local     propane/LP
gas   company
3.   Replace  burner  orifice
4.   Reconnect    leads (
see   wiring
diagram
)
5.  Replace  battery  in  transmitter
and  receiver
ODS/pilot  lights  but  flame is
continuous igniting and the main
burner couldn’t be lit.
Press ON/OFF button  again
     until air    is removed  .
2