Cape Cod Wood Stove
R
INSTALLATION
CONNECTION TO A METAL 
PREFABRICATED CHIMNEY
When  a  metal  prefabricated  chimney  is  used, 
the  manufacturer’s  installation  instructions  must  be 
followed precisely.  It will be necessary to install the 
ceiling support package or wall pass through, and “T” 
section  package,  firestops  (when  needed),  insulation 
shield,  roof  flashing,  chimney  cap,  and  any  other 
materials  deemed  necessary  by  the  instructions  of 
manufacturer of the prefabricated chimney.  Maintain 
the proper clearance to the structure as recommended 
by  the  manufacturer.    This  clearance  is  usually  a 
minimum of 2", although it may vary by manufacturer 
or for certain components. Follow the manufacturers’ 
instructions carefully.
There are basically two methods of metal chimney 
installation.  One method is to install the chimney inside 
the residence through the ceiling and the roof. Install 
an  attic  insulation  shield  to  maintain  the  specified 
clearance to insulation.  Insulation in this air space will 
cause a heat buildup which may ignite the ceiling joists. 
This  method  of  installation  requires,  at  minimum,  a 
ceiling support package, an insulation shield and roof 
flashing. See Figures 13 and 14.
LISTED  FACTORY-BUILT  CHIMNEY:   Your  Cape  Cod  requires a  6"  diam-
eter  pipe.    Follow  the  installation  instructions  provided  by  the 
chimney  manufacturer and  maintain  the  specified  clearances  to 
combustibles.
When  using  a  factory-built  chimney,  make  sure  it  is  safety  listed,  Type  UL103 
HT  CLASS  “A”  or  conforming  to  CAN/ULC-S629M,  STANDARD  FOR  650°C 
FACTORY-BUILT CHIMNEYS.
The  other  method  is  to  install  an  exterior 
chimney that runs up the outside of the residence.  
See Figures 15 and 16.  (The components illustrated 
may not look exactly like the system you purchase, 
but they demonstrate the basic components necessary 
for a proper and safe installation.)
The chimney must be the required height above 
the roof or other obstruction for safety and for proper 
draft operation.  The requirement is that the chimney 
must  be  at  least  3'  higher  than  the  highest  point 
where it passes through the roof and at least 2' higher 
than the highest part of the roof or structure that is 
within  10'  of  the  chimney,  measured  horizontally. 
(See Figure 6, page. 12)