Cape Cod Wood Stove
R
(In inches and millimeters)  
FIGURE 4 
In a Masonry Fireplace OR Through the Wall:  Six inch (6") diameter listed double wall air insulated connector pipe with 
listed factory-built Class “A” chimney or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) 
Additional specifications include a maximum 8" deep mantel without heat shield and the following clearances:                      
      A           B                   C                  D                   E            F                          G                          H                   I
    N/A       N/A         27.5"(698)     18"(457)           N/A       N/A      41"(1041) / 15"**(381)      N/A               12" (305), 
                                                                                                                                                                             6"*(152)
CLEARANCES
FIGURE 4
**Maximum 8" deep mantel with heatshield spaced 
1" from bottom mantel surface.
*With 52" high x 42" wide wall protection spaced 1" 
from combustible surface..
If further clearances are needed, obtain requirements for construction of a protected wall from 
your local building code authorities and their allowable reductions of the listed clearances.
WALL PROTECTOR SPECIFICATIONS: 
MUST BE A MINIMUM OF 24 GAUGE 
SHEET METAL WITH A 1" (25
MM
) AIR 
SPACE BETWEEN SHEET METAL AND 
COMBUSTIBLE WALL.  SHEET METAL 
MAY THEN BE COVERED WITH BRICK 
OR TILE.
MINIMUM CLEARANCES TO COMBUSTIBLES
                             CAUTION!
The  baffle  and  kaowool  blanket  placement  is 
crucial to the optimum performance of the Cape 
Cod.  Follow the steps on pages 32 & 33 (Chimney 
Cleaning), carefully to ensure proper placement of 
baffles and kaowool at time of initial installation 
and following chimney cleaning.
REAR VENT INSTALLATIONS
G
G
I
Max 8"
CL
26-5/8"