Procom QL300RYLA User Manual

Page of 25
3
I M P O R T A N T:
   
  R e a d       t h i s
owner’s  manual  carefully  and
completely  before trying  to
assemble, operate, or  service
this  heater. Improper  use  of
this  heater  can  cause  serious
injury  or  death  from  burns,
f i r e ,     e x p l o s i o n ,     e l e c t r i c a l
shock,  and  carbon  monoxide
poisoning.
SAFETY  INFORMATION  WARNINGS
 DANGER:
  
Carbon  monoxide
poisoning  may  lead  to  death!
Propane/LP  Gas:
   Propane/LP  gas
is odorless. An  odor-making  agent
is added  to  Propane/LP  gas.  The
o d o r   h e l p s     y o u     d e t e c t     a
Propane/LP  gas  leak.  However,
the odor added to   Propane/LP gas
can  fade. Propane/LP   gas  may  be
present  even  though  no  odor
exists.
Natural Gas:
  Natural  gas  is  odorless.
An odor­making agent is added to
natural  gas. The  odor  helps  you
detect a natural gas leak. However, the
odor added to natural gas can
fade.  Natural  gas  may  be present
e v e n   t h o u g h   n o   o d o r   e x i s t s .
M a k e     c e r t a i n   y o u   r e a d   a n d
understand  all  warnings. Keep  this
manual  for  reference.  It  is  your  guide
to  safe  and  proper operation
of  this  heater.
       
WARNING:   
Any  change  to
this  fireplace  or  its  controls  can
be  dangerous.
       
WARNING:  
Do not allow fans to
blow directly into the heater. Avoid any
drafts  that alter burner flame patterns.
Ceiling fans can create drafts that
alter burner flame patterns. Altered
burner  patterns can cause sooting.
Do  not  place  clothing  or  other
flammable material on or  near  the
appliance. Never place any  objects
in  the  fireplace.
Due   to   high   temperatures,   the
appliance  should  be  located  out  of
traffic  and  away  from  furniture
and  draperies.
       
WARNING:  
Do not use a blower
insert, heat exchanger insert, or other
accessory  not approved for use with
this heater.
Heater becomes very hot when
running fireplace. Keep children and
adults  away   from  hot  surfaces  to
avoid burns or clothing ignition.
Fireplace  will  remain hot   for a
time after shutoff. Allow surfaces
to     cool before  touching.
Carefully supervise young children
when they are in the room with the
fireplace.
You must operate this heater with
the heater screen in place. Make
sure the heater  screen is in place
before  running  heater.
Keep the appliance area clear and
free from combustible materials,
gasoline, and  other  flammable
vapors  and  liquids.
1.   This   appliance   is  only  for  use
      with   the  type  of  gas  indicated
      on  the  rating  plate. This
      appliance  is  not  convertible  for
      use  with  other  gases.
2.   Do  not  place  Propane/LP
      supply  tank(s)  inside
 
 any
      structure. Locate  Propane/LP
      supply  tank(s)  outdoors.
3.   If  you  smell  gas
   
Shut  off  gas  supply.
   
Do  not  try  to  light  any  appliance.
   
Do  not  touch  any  electrical  switch:
       do  not  use  any  phone  in  your
       building.
   
Immediately  call  your  gas  supplier
       from a neighbor’s  phone.  Follow
       the  gas supplier’s  instructions.
   
If  you  cannot  reach  your  gas
      supplier,  call  the  fire  department.
Carbon   Monoxide   Poisoning:
Early  signs  of  carbon  monoxide
poisoning  resemble  the  flu, with
headaches, dizziness, or  nausea.
If   you  have  these  signs, the  heater
may  not  be  working  properly. Get
fresh  air  at  once! Have  heater
serviced. Some  people  are  more
affected  by  carbon  monoxide  than
others. These  include  pregnant
women, people  with  heart  or  lung
disease,  anemia, those  under   the
influence of  alcohol,  and  those
at  high  altitudes.
4.   This heater shall not be installed
in a bedroom or bathroom.
5.   Do not use this heater as  a
wood-burning heater. Use only
the logs provided  with the heater.
6.   Do not add extra logs or ornaments
      such as pine cones, vermiculite, or
rock wool.Using these added items
can cause sooting. Do not add lava
rock around base. Rock and debris
could fall into the control area of
heater. After servicing, always
replace screen before operating
heater.
7.  
You must operate  this  heater  with
the heater screen in place. Make
sure heater screen is   in  place
before running heater.
8.  This heater is designed to be
smokeless. If logs ever appear to
smoke, turn heater off and call a
qualified service person. Note:
During initial operation, slight
smoking could occur due to log
c u r i n g   a n d   h e a t e r   b u r n i n g
manufacturing residues.
9.  To prevent the creation of soot,
follow the instructions in 
Cleaning
and Maintenance