Sony MKE-9040M User Manual

Page of 36
1-1
MVE-9000 IM
Section 1
Installation
1-1. Operating Environment
Operating guaranteed temperature :
+5 dC to +40 dC
Performance guaranteed temperature :
+10 dC to +35 dC
Operating humidity :
10 % to 90 %
(relative humidity)
Storage temperature :
_20 dC to +60 dC
Mass (when all options are installed) : Approx. 27 kg
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights.
. Dusty areas
. Areas subject to vibration.
. Areas with strong electric or magnetic fields.
. Areas near heat sources.
. Areas subject to electrical noise.
. Areas subject where is subjected to static electricity.
Ventilation
The inside of the MVE-9000-C is cooled by a fan (both
sides).
The power supply can be damaged if the exhaust vent
(both sides) and air intake (front panel) are blocked or the
fan is stopped.
Therefore, leave a blank space of more than 10 cm in the
front and both sides of the MVE-9000-C.
1-2. Power Supply
1-2-1. Power Specifications
A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.
Power requirements :
AC 100 to 240 V 
±10 %
Power frequency :
50/60 Hz
Current consumption (when all options are installed) :
6.0 to 2.5 A
m
. As the inrush current at turn-on is a maximum 110 A (at
100 V)/220 A (at 240 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source braker will operate or the unit will
abnormally operate.
. The MVE-9000 contains the single power supply unit as
the standard configuration. A maximum of two power
supply units may be installed. When starting up the
MVE-9000, be sure to turn on the power of one or more
power supply units.