Installation of Wall Venting Kits
Direct Vent Kit
VENT TERMINAL
RADIATION SHIELD
-min 1"
-max 60"
Direct Vent
Direct Vent Details
1. Move the stove to its position;
2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the
opening should be at about 23 ½ “above the base of the stove;
Note: Horizontal run should have a slope of ¼ in per foot.
3. Make a 10-1/2" x 10-1/2" opening in the wall, 23-1/2"
inches in order to introduce the radiation shield thru
the wall;
the wall;
4. Cut the radiation shield to length if necessary and
install as shown. Secure with four #10 1” wood screws;
5. Install the vent terminal (13) with 2 ½ screws (12). You
may want to remove the vent casing for easy access
and manipulation, Keep only in place the wall plate
and manipulation, Keep only in place the wall plate
6. Insert the 8 in. pipe into the round opening of the
interior black wall plate (7). Fix the insulation pad (9)
around the 8 in. pipe with the aluminum tape;
around the 8 in. pipe with the aluminum tape;
7. Keeping the insulation joint of the 8 in. pipe down,
insert it into the vent terminal wall plate;
8. Secure the 8 in. pipe to vent terminal wall plate with
the metal screw;
9. Fix finally the vent terminal wall plate with six 2 ½ in
screws (12).
10. Insert the 5 in. flexible pipe (3) into the 8 in. pipe and
fix it to the vent terminal casing. Use high temperature
silicone and one locking band to secure it in pace;
silicone and one locking band to secure it in pace;
NOTE: All joints must be sealed with RTV silicone, 315
°C.
(600
°F) temperature resistance.
11. Install the vent casing and the cover in place
12. Seal around the terminal to prevent water leakage into
the house
CUT TO LENGTH
10-1/2" X 10-1/2"
OPENING