OPERATION OF YOUR STOVE 
For your safety 
CAUTION: 
•  A qualified installer must perform installation of the appliance, venting, piping and adjustments. 
•  During operation, this stove is hot. Do not touch. Keep children, clothing and flammable materials 
away 
• 
Hot when in operation. Keep children, furniture, clothing and flammable material away 
from the appliance.
 
•  Make sure your stove is in good condition. Verify that the bay window close perfectly, all controls works as 
per specification. Vents must be in perfect condition. 
•  Make sure your stove has been fabricated in respect with the type of gas you are using. Refer to the rating 
plate installed on the back of your stove. 
•  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system 
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa); The appliance 
must be isolated from the gas supply piping system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test pressures equal to or less that ½ psi ; 
•  Do not use this appliance if any part has been under water.  Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the control system and any gas control, which has been 
under water. Make sure that there are no obstructions in the air intake or venting system. 
•  Clear the immediate area of combustible materials, gasoline, and other flammable liquids and vapors. 
•  Make sure that the gas log is in its proper place. 
Lighting Instructions  
During the first few hours of operation the appliance will release an odor. This is caused by the burning off of 
residual oils used in the manufacturing process and by the curing of the high heat paint. Open a window to get 
fresh air inside the house. The ceramic glass window may require cleaning after this initial fire. Please read 
the instructions on cleaning in the MAINTENANCE section before doing so. 
First Lighting 
WARNING :  If you do not follow these lighting instructions exactly, a fire or explosion may result causing 
property damage, personal injury, or loss of life. 
•  Open the pedestal cover front panel to reach the control. 
•  Make sure the gas control knob is turned to the "OFF" position. If it is not, press knob slightly and turn 
clockwise 
to the "OFF" position. Do not force the gas control knob. If the gas control was in the on 
position you should wait 5 minutes before trying to re-light the stove. 
•  If you smell gas STOP and follow instructions on the COVER page. 
•  Locate the pilot on the left side Push in and turn gas control knob counterclockwise 
to the "pilot" 
position. 
•  Press gas control knob in and hold. Immediately push the red igniter button repeatedly until pilot flame 
ignites. Continue holding in the control knob for 5 to 10 seconds, and then release it. If the pilot flame goes 
out, repeat this step. 
Note: you might have to push couple of times the igniter (red button) before getting a pilot flame. 
•  Push and turn gas control knob counterclockwise 
4
 to the "ON" position. The burner flame will light. 
IMPORTANT NOTE: 
 The gas valve is equipped of a thermopile (thermo generator) and a thermocouple. The thermopile while 
warm up by the pilot flame supplies the necessary energy to the operation of the gas control valve. As 
long as there’s no flame failure, the valve let the gas flowing in the stove. 
 Let your stove cool down between two lightings: If you attempt to relight your appliance while the 
thermocouple is still warm, the control valve won’t let the gas flow to the burner. Wait few minutes to cool 
the thermocouple down.