Enviro 1200 Freestanding User Manual

Page of 45
29
Installation
The  flue  collar  is  removable  for  installations 
into fireplaces with low openings
a)  Remove the first two (2) front secondary 
air tube and ceramic baffles, if installed 
(see C
ERAMIC
 B
AFFLE
 I
NSTALLATION
).
b)  Unscrew  the  nut  on  top  of  the  inside 
of  the  firebox,  using  a 
9
/
16
”  wrench  or 
socket  (see  Figure  31).  The  flue  plate 
clamp will slide off the hook/clamp.
c)  Pull  the  hook/bolt  and  the  removable 
flue collar off the top of the unit.
Figure 32: Attaching removable flue.
Figure 33: Leveling leg.
Nut
Hook/bolt
Flue plate clamp
d)  Attach the flue collar to the venting pipe using 
sheet metal screws.
e)  Push the unit into place while trying to keep the 
collar attached to venting close to the opening 
on the top of the unit.
f)  Using the hook/bolt, grab the flue collar by the 
rod through the center and pull it into place (see 
Figure 32). 
g)  Slide the flue plate clamp over the end of the 
hook/bolt  and  screw  the  nut  back  on  to  the 
hook/bolt.
h)  Re-install  ceramic  baffles  and  the  first  two  (2) 
front  secondary  air  tube  (see  C
ERAMIC
  B
AFFLE
 
I
NSTALLATION
).
3. There are two (2) leveling legs (shown in Figure 33), 
one on each side, at the back of the unit. Adjust the 
legs using a 
9
/
16
” wrench to ensure the unit is stable.
Figure 31: Attaching removable flue.
4. Screw or nail the metal plate provided by the manufacturer to the 
inside of the fireplace.
METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE 
A  FIREPLACE  INSERT  AND  SHOULD  BE  INSPECTED  BY  A  QUALIFIED 
PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”