WIRING THE CONNECTOR(S)
Use 12 ga. solid copper wire when feeding the connector(s). Each
circuit is rated for 120V, 60Hz, 20 AMPs.
NOTE: The "L", "T", "X", and In-Line Connector allow for multiple
circuits to be introduced into them. The Connectors are not polarized
and can be installed into the track in any orientation. Therefore,
identification of the circuits during wiring needs to be controlled by
the installer or electrician. The brass screw terminals are for the hot
leads. The silver screw terminals are for the neutral leads, and the
terminals marked "GND" are for the ground. The individual circuit(s)
are arranged vertically. (See diagrams). The "L" and In-Line
Connectors are pre-wired. These wires may be removed if the wiring
needs to be different. Loosen the screw terminals and remove the
wires.
1. Form the wires to the screw terminals, strip the insulation
back 1/2".
2. Slip the wire under the terminal screw head. Tighten all screw
terminals when wiring is completed.
3. Snap bottom cover onto the connector to cover the wires.
Use 12 ga. solid copper wire
for feed connections
including ground.
.50
Ground Terminal
Power
Terminals
Neutral
Terminals
Two wires may be
attached to one
screw terminal.
"T" CONNECTOR
IN-LINE
Circuit 1
Circuit 2
"L" CONNECTOR
"X" CONNECTOR
FIG. 4
Installation Instructions for Recessed ProSpec, In-Line, "L",
"T", and "X" Connectors /Circuit Diagrams
For use with Recessed ProSpec
 Track System Only.
Circuit 2
Neutral 2
Circuit 1
Neutral 1