Lightolier SC Series Leaflet

Page of 2
Cleanlite Enclosed Industrial Fluorescent
SC Series
Page 2 of 2
Damp and Wet Locations, 1, 2 or 3 Lamp T5 or T8
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: SC4DC232120SO
Options/Accessories
Tamperproof Latches: Suffix: TP.
Optional Lenses: Lexan lenses or DR acrylic lens. Consult factory.
Specifications
MaterialsChassis shall be 20 gauge steel.
Wireway Cover: Full length retained by fasteners for quick removal and
convenient servicing.
Lens: One-piece flanged lens enclosure molded from .125" thick smooth water-
clear virgin acrylic. Lens enclosure shall be heavy-duty enclosed and gasketed
with closed-cell foam gasketing (permanently attached to fixture housing).
Latches: Lock-tight cam action.
FinishChassis shall be phosphate primed and finished in baked white acrylic
enamel for not less than 86% reflectivity.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
SC
Cleanlite:
Industrial
Fluorescent
for
Damp
Locations
Number of
Lamps in
Width:
1, 2 or 3 Lamps
32
Lamp/Watts
(By others)
32 = 32W T8
28 = 28W T5
54 = 54W T5
(Nominal 48")
Options:
Add appropriate
suffix to catalog
no, ie: (TP)
4
Fixture
Length
= 4' Length
Location:
= Dry and
Damp
Locations
=Wet 
Locations
C
Lens:
= Clear
Lightolier 
                               
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section 7/Folio Q30-21 Rev. C
0.0
45.0
90.0
FLUX
0
1032
1032
1032
5
1022
1034
1047
15
979
1020
1057
25
899
992
1068
35
785
940
1058
45
642
870
1070
55
473
818
983
65
290
667
806
75
124
493
653
85
27
311
458
90
12
231
367
Model No. SC4DC232120SO
LER = FP - 72.8
IW - 53.8
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.30
Report Number: G92060
Catalog Number: SC4DC232120SO
Lamps: F32T8
Luminaire: Cleanlite enclosed industrial
with clear one-piece acrylic lens.
Ballast: Triad B232I120RH-A
Report is based on 2850 Lumens per lamp.
Efficiency: 79.0%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.5
Shielding Angles:
90
90
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
4256.
4473.
5156.
55
3770.
4644.
5139.
65
3020.
4376.
4769.
75
1939.
3978.
4608.
85
903.
3389.
4159.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 80 75 71 71 68 65 67 64 62
0
2 71 64 58 60 56 51 57 53 49
0
3 64 56 49 52 47 42 49 44 40
0
4 58 49 42 46 40 35 43 38 34
0
5 53 43 36 41 34 30 39 33 29
0
6 49 39 31 37 30 26 35 29 25
0
7 45 35 28 33 27 22 31 26 22
0
8 42 32 25 30 24 20 29 23 19
0
9 39 29 22 28 22 18 26 21 17
10 37 27 20 25 20 16 24 19 16
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
846
15.0
19.0
0
0-
0
40
1431
25.0
32.0
0
0-
0
60
2792
49.0
62.0
0
0-
0
90
4170
73.0
92.0
90-180
350
6.0
8.0
0
0-180
4520
79.0
100.0
ZONAL LUMEN SUMMARY
Ballast Type:
<
20THD
<
10THD
1 & 2 Lamp Elec. T8
SO *
H
*
1-3 Lamp Elec. T8
O3 *
H3 *
1 & 2 Lamp 28W Elec. T5
P
1 & 2 Lamp 28W or 54W Elec. T5
PG ††
1-3 Lamp 54W Elec. T5
PU ††
LOL T8 Dimming
PS
*
Other dimming options. Consult factory.
* Instant Start Standard
† Instant Start (120, 277).
†† Program Rapid Start (UNV only).
NOTE: 
For T8 UNV, you must use H
IH3 Ballast Code.
0.0
45.0
90.0
FLUX
0
2538
2538
2538
5
2507
2537
2569
242
15
2401
2525
2593
709
25
2213
2410
2569
1109
35
1943
2265
2516
1412
45
1602
2084
2336
1554
55
1194
1770
2050
1532
65
742
1439
1839
1372
75
320
1138
1433
1069
85
69
575
782
574
90
26
391
581
95
54
296
520
309
105
44
68
197
115
115
24
72
57
53
125
15
54
63
39
135
10
22
49
20
145
0
0
20
5
155
0
0
0
0
165
0
0
0
0
175
0
0
0
0
180
0
0
0
0
Model No. SC4DC354120PG
LER = FP - 66.0
IW - 154.9
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.64
Report Number: G2005352
Catalog Number: SC4DC354120PG
Lamps: F54T5 HO
Luminaire: Cleanlite enclosed industrial 
with clear one-piece acrylic lens.
Ballast: QTP2X54T5/UNV PSN
Report is based on 4400 Lumens per lamp.
Efficiency: 76.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.5
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
9560.
10660.
10455.
55
8568.
10308.
10046.
65
6941.
10084.
10303.
75
4495.
10407.
9715.
85
2070.
7912.
6981.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 80 76 72 70 67 64 66 64 61
0
2 72 65 59 60 55 51 57 53 49
0
3 65 56 49 52 46 42 49 44 41
0
4 59 49 42 46 40 35 43 38 34
0
5 54 44 36 41 34 30 39 33 29
0
6 50 39 32 36 30 26 35 29 25
0
7 46 35 28 33 27 23 31 26 22
0
8 43 32 25 30 24 20 29 24 20
0
9 40 29 23 28 22 18 26 21 18
10 38 27 21 25 20 16 24 19 16
ZONAL LUMEN SUMMARY
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
2061
15.6
20.4
0
0-
0
40
3473
26.3
34.3
0
0-
0
60
6559
49.7
64.8
0
0-
0
90
9574
72.5
94.7
90-120
477
3.6
4.7
90-130
516
3.9
5.1
90-150
541
4.1
5.3
90-180
541
4.1
5.3
0
0-180
10115
76.6
100.0
Voltage:
120, 277 or