AC Power 
This product has an auto-ranging power supply that can work with an input 
voltage range of 100~240 VAC, 50/60 Hz. 
 
 
AC Plug 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow/Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
 
 
Replacing the 
Fuse  
1. 
Disconnect this product from power. 
2. 
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap 
from the housing. 
3. 
Remove blown fuse and replace with a good fuse of the same type and 
rating. 
4. 
Screw the fuse holder cap back in place and reconnect power. 
DMX Linking 
The Legend™ 330SR Spot  will work with a DMX controller using a regular 
DMX serial connection. A DMX Primer is available from 
 
 
 
DMX Connection 
The Legend™ 330SR Spot uses a regular DMX data connection for its DMX 
personalities:  Mode1  (21)  and  Mode2  (27). See the User Manual to connect 
and configure for DMX operation. 
Mounting 
 
Product 
Mounting 
Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Control Panel 
Description 
Button 
Function 
<MENU> 
Exits from the current menu or function 
<ENTER> 
Enables the currently displayed menu or sets the 
currently selected value into the selected function  
<UP> 
Navigates upwards through the menu list and 
increases the numeric value when in a function 
<DOWN> 
Navigates downwards through the menu list and 
decreases the numeric value when in a function  
 
 
 
Secure the safety cable using 
the passageway on the back 
of the product. 
Overhead Mounting 
Floor Mounting 
Safety Cable 
(works with CH-05 from 
CHAUVET®) 
Mounting Clamps 
(such as CLP-15 or CLP-15N 
clamp from CHAUVET®)