Technical data 
 
5.2 
Technical data for IP-Module CVVA-IP 
 
 
Electrical supply 
12 V DC/24 V AC 
Power requirement 
max. 6.0 W 
Operating temperature range 
-10 – +50 °C, max. relative humidity 90% 
Storage temperature range 
-20 – +60 °C, max. relative humidity 70% 
Dimensions (H x Ø) 
48 x 135 mm 
Weight 620 
Material Aluminum 
IP rating 
IP66 
System requirements 
All systems, which feature TCP/IP network functions and provide an 
http browser (Microsoft Internet Explorer from version 5.5 with Java 
plug-in or Mozilla or Netscape from version 7.0). 
Protocols 
ARP, BOOTP/DHCP, TCP/IP, HTTP, ICMP, SNMP, FTP and DNS 
Installation 
IP address configurable via ARP, BOOTP/DHCP, connection to twisted-
pair RJ45 Ethernet. 
Network connection 
10BaseT Ethernet or 100BaseTX Fast Ethernet, auto-sensing, full/half 
duplex 
Image formats 
 
QCIF (176x144), 
 
CIF (352x288), 
 
4CIF (704x576) (interlaced). 
Image transmission 
Motion JPEG (multipart/x-mixed-replace content type), user 
configurable JPEG single image frame quality, streaming up to 25 
images per second with QCIF and CIF or up to 10 images per second 
with 4CIF. 
Security 
Separate passwords for image access and system configuration. 
Hardware 
8 MB RAM, 16 MB flash ROM 
 
10 
Siemens Building Technologies 
 
Fire Safety & Security Products