Fire alarm systems 
Alert annunciation units 
1735 and 1736 
•  Control and indicating unit for alert annunciation 
•  Compact size 
Alert annunciation unit 
When the Alert  Annunciation function shall 
be used in the systems EBL512 & EBL128 
an  AA unit is required to present the AA 
alarms and for the related manoeuvres, i.e. 
to acknowledge / reset the alarms.  For a 
detailed description of the AA  function, see 
Planning and Operating instructions for the 
system respectively.   
 
Point or zone alarm presentation is as in the 
c.i.e. it is connected to.  When there are 
queued alarms in the system, you can scroll 
amongst them.  All or selected alarms will 
be presented in the unit's display (LCD, 
2x40 characters with back-light).  A user 
definable text message will be presented 
together with each alarm, if programmed in 
the c.i.e.  Furthermore, > 617 texts can for 
selected alarms be stored in the unit and will 
in that case be shown, instead of the texts 
sent from the c.i.e. for these alarms.  A built-
in buzzer will sound to indicate a not 
acknowledged AA alarm.  The unit is power 
supplied via the c.i.e. or ext. power supply. 
LEDs, push buttons etc. 
The unit has the following LEDs: 
•  Fire and Alarms queued, indicating fire 
alarm / AA alarm. 
•  Operation, indicating that the AA 
function is enabled in the system.  
Normally a time channel is used to 
enable this function. 
•  Fire brigade alerted, indicating that the 
"Fire brigade tx" output is activated in 
the c.i.e. because: 
-  the activated alarm is not an AA alarm 
-  the AA function has been ended, e.g. 
the acknowledge or investigation time 
has run out, etc. 
•  Acknowledge, indicating that the AA 
alarm has been acknowledged. 
The unit has the following push buttons: 
•  Alarms queued, used to scroll amongst 
the alarms. 
•  Acknowledge, used to acknowledge an 
AA alarm and hereby also silence the 
buzzer. 
•  Reset, used to reset an AA alarm. 
1735 has the designation texts in Swedish. 
1736 has a neutral front for other languages, 
see the opposite side of this page.  (This 
front also holds one extra LED & two extra 
push buttons.) 
Compact size 
The compact size enclosure is made of grey 
high impact ABS.  Fitted with a supple-
mentary "O" ring gasket, it will comply with 
IP61, in respect of dust and moisture.  The 
unit has no door, i.e. the front is accessed 
directly, when required.  The push buttons 
are disabled until they are supposed to be 
used.  The unit shall be wall mounted.  Two 
compression glands are attached. 
SW mode and address setting 
The display and the push buttons are used to 
set the SW mode and address.   
The SW modes are described on the 
opposite side of this page. 
Product application 
The units are intended for indoor use and in 
dry premises.  They are intended to be used 
in the systems EBL512 & EBL128.  An 
External FBP / DU interface board 1587 is 
required in the EBL512 c.i.e. and a 4552 
Transceiver component in the EBL128 c.i.e.