First Alert SA305B Leaflet

Page of 2
DUAL IONIZATION
Dual Ionization sensing chamber.
Generally more effective at
detecting small particles produced
by flaming fires. Sources may
include paper or kitchen grease.
SILENCE FEATURE 
Silences and tests alarm with a single 
button.
TWO LOCKING 
FEATURES
Pins are provided to lock battery drawer 
and/or alarm to base. Perfect for
apartment, dormitory or hotel
applications.
EASY ACCESS 
BATTERY DRAWER
APPROVED FOR
RV USE
Available in the following versions:
SA303B  Carbon Zinc Battery
SA305B  Long Life Lithium Battery
Listed to
Standard
UL 217
CAT. 
SA303B/SA305B
S M O K E
A L A R M
9V Battery Powered
Description:
First  Alert  Model  SA303  (cat  no.  SA303B  and  SA305B)  are  battery  operated 
single  station  ionization  sensor  smoke  alarms  specifically  designed  for 
residential  and  institutional  applications  including  sleeping  rooms  of  hospitals, 
hotels,  motels,  dormitories,  and  other  multifamily  dwellings  as  defined  in 
standard  NFPA  101.  Model  SA303  has  been  fully  tested  and  complies  with, 
UL217,  CSFM,  NFPA  72,  and  NFPA  101  and  other  agencies  that  model  their 
codes  after  the  above  agencies.  They  meets  building  codes  where  battery 
operated  ionization  sensor  with  silence  smoke  alarms  are  required  and  with 
model  building  codes  published  by  the  ICC.  SA305B  meets  codes  where  a 
removable lithium battery powered alarm is required.
First Alert Model SA303 is a state of the art smoke alarm designed to provide 
early warning of a fire. It features a dual ionization smoke sensing chamber, an 
85dB horn, a supervised 9V carbon zinc battery power supply for cat no. SA303B  
and a lithium battery power supply for cat no. SA305B, a single button 
test/silence switch, a silence feature to silence unwanted nuisance alarms, a red 
LED light that indicates DC power or alarm. It also features tamper resistant 
locking pins that lock the alarm to the mounting bracket and/or the battery 
drawer to prevent removal of battery. Battery installation and removal can occur 
while the unit is mounted to the ceiling or wall via the swing open battery 
drawer. When battery power drops to a pre-set warning level, the horn will 
“chirp” approximately once per minute to indicate a fresh battery is needed. 
Designed for wall or ceiling mounting. Includes mounting anchors and screws. 
Both cat no.'s are approved for use in recreational vehicles.