American Standard 8971 Series Leaflet

Page of 2
M 6 6 2 3 2   R e v. 1 . 1
HANDSHOWER INSTALLATION (Mode 8971 series only)
SERVICE
TEST INSTALLED FAUCET
To change direction of handle rotation, 
proceed as follows:
Turn valve to OFF position.
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90p and replace.
Replace SPRING CLIP (1).
Replace ADAPTER, HANDLE, SCREW, and
INSERT.
Plastic SCREEN (3) in CARTRIDGE (4) may accumulate
dirt causing reduced water flow. To clean, first
turn off hot and cold water supplies, then:
Remove HANDLE (see above).
Unscrew CARTRIDGE (3) with wrench.
Thoroughly rinse plastic SCREEN (4) at
base of CARTRIDGE (3).
Replace CARTRIDGE (3) until flange is 
tight against valve body.
Turn valves OFF.
Replace ADAPTER, HANDLE, SCREW,
and INSERT.
Check with local codes, and if required, add a vacuum breaker
kit (part no. 028708) at specified height.  Refer to the instal-
lation instructions supplied with the kit.
IMPORTANT
Drop ESCUTCHEON (1) through the fourth hole of the tub ledge
(12" max from SPOUT center) with HOLDER (2) directed towards
tub center. Be sure RUBBER RING (3) is properly seated in
ESCUTCHEON (1). Attach RUBBER WASHER (4) and BRASS WASHER (5)
from underside of ledge. Secure ESCUTCHEON (1) by tightening locknut.
Add SEAL WASHER (6) and connect HOSE (7) to outlet nipple on
bottom of COUPLING (10). Tighten firmly.
Unscrew HOLDER (2) from ESCUTCHEON (1). Slip SHOWER HOSE (8)
with COUPLING NUT through HOLDER (2) and ESCUTCHEON (1).
Install SEALS (6) and connect both HOSES (7, 8), attach
HOLDER (2) to ESCUTCHEON (1) and connect
HANDSHOWER (9).
When not in use, HANDSHOWER should be seated 
in the HOLDER.
NOTE
To replace SHOWER HOSE, proceed as follows:
Disconnect HANDSHOWER.
Unscrew HOLDER and pull SHOWER HOSE until hose
coupling appears.
Prevent HOSE from slipping back (use clamp, tape, etc.)
Disconnect SHOWER HOSE.
Remove HOLDER from old HOSE and slip over new
SHOWER HOSE.
Insert new SEALS and connect HOSES and HANDSHOWER.
Open valves, lift transfer knob and check for leaks.
Release HOSE, screw HOLDER back to ESCUTCHEON,
and seat HANDSHOWER.
Before the bathroom is completely finished, you may 
want to remove spout, handshower, and handles.
To remove handles, see separate "Instruction Sheet."
See separate "Instruction Sheet for handle installation.
To remove SPOUT (1), proceed as follows:
Lift TRANSFER ROD (2) and unscrew KNOB (3). (Model 3941 only).
Remove PLUG BUTTON (4) and remove SET SCREW (5)
using 5mm hex wrench supplied.
Lift SPOUT (1) off SHANK (6) carefully
and remove RUBBER RING (7).
Unscrew SHANK SLEEVE (8) and lift TRANSFFER ROD (2)
from  SHANK (6) (Model 3901 & 3941 only).
Reverse sequence to re-install SPOUT (1). Be sure
RUBBER RING (7) is properly seated in its recess at the
base of the SPOUT (1). Make certain SET SCREW (5) is
properly aligned and tight so that SPOUT (1) is locked in place.
The flow rate of this Tub Filler exceeds 20 gallons/minute
at higher water pressure. Do not fill bathtub unattended.
CAUTION
LOCKNUT
1
2
3
4
5
6
7
8
9
6
6
10
3
3
4
4
3
4
5
7
8
6
1
1
1
2
2
2
Turn VALVES 
(1) to "off" position.
Lift HAND SHOWER 
(3) from holder, direct spray into tub, lift
TRANSFER KNOB 
(4) to check HAND SHOWER (3) and HOSES for leaks.
Turn VALVES "off."
With handles in "off" position, turn on water supplies and check
all connections for leaks.
Operate both handles and flush water lines thoroughly.
Check SPOUT 
(2) mounting for leaks.
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90$.
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 1999
IN MEXICO  01-800-839-12-00