American Standard 7391.224 User Manual

Page of 3
HANDLE INSTALLATION
6
10
9
SERVICE
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90
°
 and replace.
Replace SPRING CLIP (1).
Replace ADAPTER, HANDLE, SCREW, and INSERT.
90
°
TEST INSTALLED FAUCET
With handles in OFF position, turn on water supplies and
check all connections for leaks.
M 9 6 8 0 3 2 A
LIFT ROD GUIDE INSTALLATION
4
Unscrew LIFT ROD NUT (1)from LIFT ROD GUIDE (2).
Make sure SEAL (3) is seated into ESCUTCHEON of
LIFT ROD GUIDE (2).
Drop LIFT ROD GUIDE (2) into
rear hole of bidet and from
below secure with ROD GUIDE
NUT (1).
TEE AND HOSE CONNECTION
5
WATER SUPPLY CONNECTIONS
7
1
3
2
7
6
5
3
1
2
3
1
2
4
5
6
6
Connect water supplies to FAUCET (1) with 1/2" IPS
FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply
when bending. Use tubing cutter to cut to proper length.
3
2
FERRULE
COUPLING NUT
1
NOTE: FLEXIBLE SUPPLIES ARE NOT INCLUDED AND HAVE TO BE
PURCHASED SEPARATELY.
Insert SEAL (1) into ADAPTER (2)
and tighten ADAPTER (2) to bottom
of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut
of TEE (5) and tighten connection
to ADAPTER (2)
Connect HOSE COUPLING
NUTS (6) to Hot and Cold
valve bodies and securely
tighten.
8
FINISH DRAIN INSTALLATION
Position EXTENSION ROD (1)
onto POP-UP ROD (2) and tighten
THUMBSCREW (3).
Position BIDET fixture and
secure to floor.
Insert lift rod into lift rod guide.
Using metal TAILPIECE (5), make connection to the TRAP (6).
Remove one end of CLIP (4) from
PIVOT ROD (7) by squeezing ends
together while sliding.
Insert PIVOT ROD (7) into second
or third hole in EXTENSION ROD (1)
and reassemble CLIP (4).
(EXTENSION ROD (1) may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION ROD (1) and
tightening THUMBSCREW (3).
3
1
1
2
1
7
4
6
5
2
Replace Spray and operate
handles several times from
OFF to ON position. Do not
force, handles turn only 90˚.
Spray may accumulate dirt
causing distorted and reduced
water flow. Remove spray and
rinse clean.
Operate both handles to flush water lines thoroughly. Turn
diverter to rim wash and bidet spray.
TOP
Figure "A"
SPLINE END DOWN
4
Push INDEX CAP (7) in hole of LEVER BALL (5).
Secure LEVER BALL (5) with HANDLE SCREW (6).
Find correct position of LEVER BALL (5) by adjusting male teeth on
ADAPTER (1) to female teeth in LEVER BALL (5).
Screw HANDLE BASE (3) on top of ESCUTCHEON (4) until it is snug
against stop.
Push LEVER BALL (5) through HANDLE BASE (3) onto ADAPTER (1).
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without spline is facing up. See figure "A".