CHECK DRAIN CONNECTIONS
10
11
12
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water
lines thoroughly.
Replace AERATOR (3).
1
HOT
COLD
2
4
2
1
5
“P” TRAP
WASTE
OUTLET
3
Operate POP-UP KNOB (5) and fill Sink with water.
Check that DRAIN STOPPER (4) makes a good seal
and retains water in Sink. If STOPPER (4)  does not 
seal properly, please refer to “Troubleshooting Guide” 
in these instructions.
Release POP-UP KNOB (5) down and check all 
drain connections and "P" trap for leaks.     
Tighten if necessary.
4
9
U S 6 0 3 8 5   R e v.   1 . 2
CARE INSTRUCTIONS:
SERVICE
To change direction of handle rotation, proceed as follows:
13
4
1
2
TOP
SPLINE END
DOWN
3
7
5
6
Push INDEX CAP (6) 
in hole of LEVER BALL (4).
Secure LEVER BALL (4)
with HANDLE SCREW (5).
Find correct position of 
HANDLE (4) by adjusting 
male teeth on ADAPTER (1) 
to female teeth in 
LEVER BALL (4).
Thread HANDLE BASE (3) onto
VALVE ESCUTCHEON (7)
Push LEVER BALL (4) onto
ADAPTER (1).
Push ADAPTER (1) on VALVE
STEM (2), so that the hole of the
ADAPTER (1) without spline is 
facing up.
INSTALL HANDLES
6
INSTALLATION OF OPTIONAL METAL LEVER
HANDLES (Supplied with Faucet)
Thread PORCELIAN LEVER HANDLE (2) counter-clockwise
and remove INDEX BUTTON with MOUNTING ROD ASSEMBLY (1).
Insert MOUNTING ROD ASSEMBLY (1) into METAL HANDLE (3)
and HANDLE COLLAR (4).
 
3
2
6
1
4
5
Thread HANDLE ASSEMBLY (6) into ball of HANDLE BASE (5)
and tighten. 
Turn valve to OFF position.
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90  and replace.
Replace SPRING CLIP (1).
Replace ADAPTER, HANDLE, SCREW, and INSERT.
90 
1
2
Replace Spray and operate handles several times from
OFF to ON position. Do not force, handles turn only 90˚.
Spray may accumulate dirt causing distorted and reduced
water flow. Remove spray and rinse clean.
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH  CLEAR WATER.
DRY  WITH A SOFT COTTON 
FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH 
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.