American Standard 7460.100 User Manual

Page of 4
7 5 2 8 7 7 - 1 0 0   R E V .   A
-   2   -
C/L of 2 x 6
Reinforcement
Finished
Floor
30"
762mm
Identify desired location of the console table.
Provide suitable reinforcement required for anchoring the vanity to the wall.  Centerline of reinforcement should be 30" up 
from the floor (see Figure 1).
Rough in supply lines and waste per rough in dimensions.  
Drill at least two 3/8" O.D. anchoring holes through the rear stringer of the console table at 2-1/2" down from the top of 
the table (see Figure 2).
Move the vanity into place and level with the adjustable glides on the bottom of the feet.  The glides can be adjusted 
outward up to 3/8". Anchor it to the wall through the 2 anchoring holes in the rear of the vanity (see Figure 2). Do not 
overtighten to prevent cracking the rear stringer.
VANITY TOP, SINK, AND FAUCET INSTALLATION
Install the faucet onto the granite top per the manufacturer's instructions.
Two people recommended for this installation
CONSOLE TABLE INSTALLATION
FIGURE 1
FIGURE 2
MOLDING
ADJUSTABLE
GLIDES
(LOCATED
UNDER
EACH FOOT)
3/8" ANCHORING
HOLES IN
REAR STRINGER
2-1/2"
64mm
19-1/4"
489mm
GRANITE TOP
SEALANT
Apply a continuous 1/8" bead of silicone 
sealant 1" from the inside edge of the 
console. Carefully set the stone top on the 
console table. Be sure that the top is 
centered on the table.
Use mineral spirits to remove excess silicone from the console and stone top.