Specifications
The specifications of the projector are as follows.
Power supply
AC 200 V - 240 V, 50 Hz/60 Hz
Power consumption
2 150 W (11.5 A)
0.3 W when [STANDBY MODE] is set to [ECO]
9 W when [STANDBY MODE] is set to [NORMAL]
DLP chip
Size
24.1 mm (0.95") (aspect ratio 16:9)
Display system
3-unit DLP chips, DLP type
Number of pixels 2 073 600 pixels (1 920 x 1 080 dots)
Lens
Optional
Luminous lamp
420 W, UHM lamp x 4
Light output
*1
16 000 lm
Contrast ratio
*1
10 000:1 (when [DYNAMIC IRIS] is set to [3])
Color system
7 standards (NTSC/NTSC4.43/PAL/PAL-N/PAL-M/SECAM/PAL60)
Projected image size
1.78 m (70") to 25.40 m (1 000")
*2
Screen aspect ratio
16:9
Projection method
[FRONT/CEILING], [FRONT/FLOOR], [REAR/CEILING], [REAR/FLOOR]
Power cable length
3.0 m (118-1/8")
Outer case
Molded plastic
Dimensions
Width
620 mm (24-13/32")
Height
255 mm (10-1/32") (excluding the legs)
Depth
730 mm (28-3/4") (excluding the lens mount cover)
Weight
Approx. 43.0 k] (94.8 lbs.)
*3
Noise level
*1
48 dB
Operating 
environment
Operating 
environment 
temperature
*4
0 °C (32 °F) to 45 °C (113 °F)
Operating 
environment 
humidity
10 % to 80 % (no condensation)
Remote 
control
Power supply
DC 3 V (AA/R6 battery x 2)
Operating range Within approx. 30 m (98'5") (when operated directly in front of signal receiver)
Weight
134 ] (4.7 ozs.) (including batteries)
Dimensions
Width: 51 mm (2"), Height: 176 mm (6-15/16"), Depth: 28 mm (1-3/32")
*1  Measurement, measuring conditions and method of notation all comply with ISO21118 international standards.
*2  1.78 m (70") to 7.62 m (300") when the projection lens ET-D75LE5 is attached, and 1.78 m (70") to 15.24 m (600") when the projection lens 
ET-D75LE8 is attached.
*3  Average value. Weight varies for each product.
*4  When using the projector at high altitudes (between 1 400 m (4 593') and 2 700 m (8 858') above sea level), the operating environment temperature 
should be between 0 °C (32 °F) and 40 °C (104 °F).
If you use the smoke cut filter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be 
used at high altitudes.