Runco LS-100d User Manual

Page of 114
92
Lightstyle™ Series LS-100d Installation/Operation Manual
P
RELI
M
INARY
Brightness and Contrast:
Cinema Standards Measurement System (CSMS) 
Specifications
-
Brightness: 12.7 foot-Lamberts (fL)
-
Contrast Ratio: 330:1
These measurements are taken from the projector in a controlled, 
home theater environment. All measurements are made to 
ANSI/NAPM IT7.228-1997 specifications using the Photo Research 
PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, 
Video Essentials test DVD and a DNS rear-projection, 1.0 gain, 
77-inch wide Fresnel screen. The projector is calibrated to a color 
temperature of 6,500K and has a minimum of 150 hours of usage.
The foot-Lambert (fL) is the unit of measurement used in commercial 
movie theaters to express image brightness at the screen surface. The 
Society of Motion Picture and Television Engineers (SMPTE) specifies 
16 fL as the target image brightness for film-based projectors using an 
open gate (without film in the projector). More importantly, today 
SMPTE specifies 12 fL as the target image brightness in Digital 
Cinema theaters. The foot-Lambert measurement is dependent on 
screen size, screen gain and projector light output.
Home Theater Calibration Specifications
-
Light Output: 350 ANSI Lumens
-
Contrast Ratio: 330:1
These specifications are obtained by calibrating the projector as 
described above for CSMS measurements.
Industry-Standard Specifications
-
Light Output: 600 ANSI Lumens
-
Contrast Ratio: 3 settings (Infinity:1, 20,000:1, 10,000:1 
(sequential))
ColorContrast™
Colors have up to 50% higher contrast than Mercury or Xenon 
lamp systems.
These are typical projector brightness and contrast specifications 
found in most companies’ sales literature. Runco includes these 
measurements in its literature to allow for direct comparison with other 
manufacturers’ projectors. These measurements are typically taken at 
9,000K to 13,000K to get expected performance data when the 
projector is used in professional, commercial and industrial displays.
Power Requirements:
100 to 240 VAC (auto-sensing), 50/60 Hz, 240 watts typical
(477.8 BTUs/hour), 320 watts maximum
Operating Environment:
41°F to 104°F (5°C to 40°C), 10% to 85% humidity
(non-condensing) 
Dimensions:
Weight (including lens):
27.5 lbs. (12.5 kg)
Regulatory Approvals:
FCC Part 15 Class B, CE Class B, UL, cUL, CB, RoHS, 
WEEE, local conformances as required
Limited Warranty: 
Two (2) years parts and labor from the date of shipment from 
Runco. Extended RuncoCare™, RedCarpet™, and 
PremierCare™ assurance available. 
Maintenance:
Zero maintenance, solid state optical path.
Specifications are subject to change without notice. 
Table 7-1. LS-100d Specifications (continued)