OPTION menu
Item
Description
SERVICE
(continued)
COMMUNICATION
(continued)
COMMUNICATION TYPE
Select the communication type for transmission via 
the CONTROL port.
NETWORK BRIDGE
Ù OFF
NETWORK BRIDGE: Select this type, if it is required 
to control an external device as a network terminal, 
via this projector from the computer. 
The CONTROL port doesn't accept RS-232C
commands (
Network Bridge Function in the 
User’s Manual - Network Guide)
OFF: Select this mode to receive RS-232C 
commands using the CONTROL port. 
• OFF is selected as the default setting.
• When you select the NETWORK BRIDGE, check 
the item, TRANSMISSTION METHOD (
below).
SERIAL SETTINGS
Select the serial communication condition for the 
CONTROL port.
BAUD RATE
4800bps
Ù 9600bps Ù 19200bps Ù 38400bps
PARITY
NONE
Ù ODD Ù EVEN
• The BAUD RATE is 
xed to 19200bps and PARITY 
is
xed NONE when the COMMUNICATION TYPE 
is set to OFF (
above).
TRANSMISSION METHOD
Select the transmission method for communication by 
the NETWORK BRIDGE from the CONTROL port.
HALF-DUPLEX
Ù FULL-DUPLEX
HALF-DUPLEX: This method lets the projector 
make two way communication, but only one 
direction, either transmitting or receiving data, is 
allowed at a time.
FULL-DUPLEX: This method lets the projector 
make two way communication, transmitting and 
receiving data at the same time.
• HALF-DUPLEX is selected as the default setting.
• If you select HALF-DUPLEX, check the setting of 
the item RESPONSE LIMIT TIME (
62).