Electro-Voice PA1250T User Manual

Page of 40
100V
25W
100V
25W
16 x 25W
100V
6W
100V
6W
66 x 6W
PA2450L & PA4150L
Loudspeaker systems connected to channels A and B (or C and D) have to be 
connected according to the polarity indicated. Please, make sure to mind the 
minimal impedance of 4 ohms per channel.
For bridged operation, the load has to be connected according to the BRIDGED-
label and the Mode switch needs to be set to “Bridged”. Please, make sure to 
keep in mind that in Bridged Mode the minimal impedance is 8 ohms and that 
the input audio signal has to be fed to channel A (or C).
REAR PANEL
Loudspeaker Outputs
The speaker output jacks are suitable for connecting speaker cables with a maximum diameter of 2.5 
mm
2
. The provided  screwlock  connectors  can  be  screwed  to the power  amp  to prevent  inadvertent 
disconnection.  Power  amps  offer  low  impedance  outputs  and  /  or  floating  outputs  (ISOLATED 
OUTPUTS) with nominal voltages of 50V, 70V and 100V, depending on the amp model.
Caution:  The symbol of a FLASH at the loudspeaker connectors indicates that these outputs 
may carry high voltages which, when getting in contact with, can cause serious harm. 
Establishing connections at these outputs is only permissible for persons who have 
been instructed on how to do so. Otherwise use prefabricated cables only.
PA1250T, PA2250T & PA2400T
Integrated audio output transformers convert the power amp’s nominal output voltage to 50V, 70V and 
100V. The amplifier models PA2250T and PA2400T present all voltages simultaneously at the floating 
outputs so that the power amp channels can be used in any combination of possible output voltages. 
Mixed operation of low-impedance speaker systems and floating loudspeaker lines on a single power 
amp channel is possible as well.
The use of loudspeaker systems with 100V or 70V matching transformers to reduce the effects of cable 
loss is recommended when the distance between power amp and speaker systems exceeds 165 feet. 
In addition, this also facilitates distributing the output power among loudspeakers.
As many loudspeaker systems as possible can be connected, as long as the speaker network’s overall 
power consumption does not exceed the power amp’s rated output power while at the same time not 
falling below the nominal load impedance of the power amp outputs. Please refer to specifications in 
the appendix for individual values of the rated output power and nominal load impedance of power amp 
outputs.
Configuration example: PA2400T with 100V speaker systems connected. 
Maximum working loads with 25W/100V and 6W/100V loudspeaker systems.
7