Mains Operation
The following tables provide a useful aid in determining power supply and cabling requirements. Column 
“1/8 max. output power into 4 ohms
(2)
” states the values to be used for normal operation. These results 
were measured with the power amplifier being operated at maximum output and a Pink Noise signal 
according to EN60065 applied at the input, which approximately represents the strain of an audio signal 
driving the power amp at maximum modulation.
Temperatures inside of the power amplifier
The  power  drawn  from  the  mains  network  is  converted  into  acoustic  output  to  feed  the  connected 
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred 
to as leakage power or dissipation (PD). The amount of heat resulting from power dissipation might 
remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table 
is meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the 
ventilation efforts necessary.
The column “PD” lists the leakage power in relation to different operational states. The column “BTU/hr” 
shows the dispensed heat amount per hour.
PA2450L
Umains
[V]
Imains
[A]
Pmains
[W]
Pout
[W]
PD
[W]
BTU/
hr
(3)
idle
230
0,2
28
0
28
96
Max. output power into 8ohms
(1)
230
5,4
923
2x300
323
1102
Max. output power into 4ohms
(1)
230
8,8
1605
2x480
645
2201
1/3 max. output power into 4ohms
(1)
230
5,6
953
2x160
633
2160
1/8 max. output power into 4ohms
(1)
230
3,7
598
2x60
478
1631
1/8 max. output power into 4ohms
(2)
230
3,2
530
2x60
410
1399
1/8 max. output power into 4ohms
(2)
 
(4)
253
3,6
629
2x73
484
1651
Normal Mode (-10dB) into 4ohms
(1)
230
3,2
550
2x48
454
1549
Rated output power (0dB, rated) into 4ohms
(1)
230
8,1
1482
2x450
582
1986
Alert-Mode (-3dB) into 4ohms
(1)
230
6,1
1065
2x225
615
2098
PA4150L
Umains
[V]
Imains
[A]
Pmains
[W]
Pout
[W]
PD
[W]
BTU/
hr
(3)
idle
230
0,4
54,7
0
55
187
Max. output power into 8ohms
(1)
230
3,9
653
4x100
253
863
Max. output power into 4ohms
(1)
230
6,3
1126
4x160
486
1658
1/3 max. output power into 4ohms
(1)
230
4,0
665
4x53
452
1541
1/8 max. output power into 4ohms
(1)
230
2,7
428
4x20
348
1187
1/8 max. output power into 4ohms
(2)
230
2,4
385
4x20
305
1041
1/8 max. output power into 4ohms
(2)
 
(4)
253
2,6
450
4x24
353
1205
Normal Mode (-10dB) into 4ohms
(1)
230
2,4
385
4x16
321
1095
Rated output power (0dB, rated) into 4ohms
(1)
230
6,1
1080
4x150
490
1638
Alert-Mode (-3dB) into 4ohms
(1)
230
4,6
790
4x75
490
1672
(1)
Sine wave 1kHz
(2)
Pink noise acc. to EN60065
(3)
1BTU = 1055.06J = 1055.06Ws
(4)
10% mains over voltage
(5)
PD = Power dissipation
The following factors allow direct proportional calculation of the mains current (
Imains)
 for different mains 
supply voltages: 100V = 2,3; 120V = 1,9; 220V = 1,05; 240V = 0,96