Panasonic SJ-MJ88 User Manual

Page of 62
4. Press the 
 key of the remote controller (“LD ” changes to “LP ” of the 
LCD).
5. Set the laser power at 600   W±10% by using VOL+ and VOL- key of the 
remote controller.
[Specified range: 600   W±10%]
Caution:
Proceeding on to the subsequent adjustment procedure with the read power 
exceeding 600   W±10% will result in damage to the optical pickup.
6. Set the laser power with the 
 key of the remote controller (“LP ” changes 
to “LDOK ” in the LCD).
7. Press the 
 key of the remote controller (“LDOK ” changes to “T0E ” on 
the LDC. 
8. Remove the laser power meter. Laser power adjustment is finished. 
[REFERENCE]
<For use of MD cartridge type laser power meter>
We recommend you to use a sensor type laser power meter for laser power 
adjustment of this set.
But if available is a MD cartridge type only, follow the procedure below.
1. Disassemble the unit so that only the mechanism unit and the printed circuit 
board are exposed. (as shown in 
Fig. 8
 )
2. Set the laser power meter cartridge. (as shown in 
Fig. 8
 )
3. Set the battery and attach and secure the battery cover with a rubber band. 
(as shown in 
Fig. 9
 )
4. Follow the steps for “6.2.1. Enter the adjustment mode”. (Subsequent 
procedures are the same as those for the sensor type.)
Fig. 8
29