Belkin AP30800fc10-BLK User Manual

Page of 32
B
elkin 
Pur
eA
B
at
tery 
B
ack
up 
3
Belkin PureAV Battery Backup Features  
and Functions
Indicator
Condition
Meaning
BATTERY ON
(Green LED)
Solid 
Green
The Belkin PureAV Battery Backup is on  
battery-backup mode and an intermittent 
audible alarm is on. The Battery Backup will 
begin shutdown procedure.
Flashing 
Green
Battery is low. The Belkin PureAV Battery 
Backup will start shutdown. The buzzer sounds 
an audible alarm.
OVERLOAD
(Yellow LED)
Solid 
Yellow
The Belkin PureAV Battery Backup shut down 
due to an overload or short-circuit condition. 
Flashing 
Yellow
Battery output is drawing more power than the 
Battery Backup can provide.
REPLACE
 BATTERY
(Red LED)
Solid 
Red
Battery is weak or bad; the battery needs  
to be replaced.
SITE WIRING
FAULT
(Red LED)
Solid 
Red
There is either no ground circuit or a     
reversed polarity in the building wiring.
LOAD
(Yellow LED)
Solid 
Yellow
This display shows the Belkin PureAV Battery 
Backup output load percentage level of 17%, 
33%, 50%, 67%, and 85%.
BATTERY
(Green LED)
Solid 
Green
This display shows the battery capacity
percentage level of 20%, 40%, 60%, 80%, and 
100%.
On/Off/Test Switch
LED Indicator
Site Wiring Fault
Battery On
Battery
Load
Replace Battery
Overload