1. Place the powerhead on a clean, flat
surface, spark plug facing up.
See Figure 5.
2. Use the 4mm hex wrench to loosen
the tube clamp screw. Verify that the
D-shaped shim washer is positioned as
shown in Figure 6.
Tube
Clamp
Shim
Washer
CAUTION!
Do not remove the D-shaped shim
washer! The shim washer prevents
damage from overtightening the tube
clamp screw.
Connect the Outer Tube to the
Powerhead
CAUTION!
Do not force the shaft tube into the
powerhead! Excessive force can
damage the shaft tube or mainshaft.
Clamp
Screw
Figure 5
Figure 6
Assembly: Mainshaft/Powerhead
Throttle
Trigger
Ignition
Switch
Hex
Wrench
3. Add some moly-type EP grease to the
splines on the end of the mainshaft.
4. Slide the outer tube into the tube
clamp until the tube bottoms.
5. Position the outer tube so that the
ignition switch is facing up and the
throttle trigger is down.
6. Slide the outer tube into the power-
head until the throttle grip just
contacts the tube clamp.
7. Tighten the clamp screw firmly.
Assembly: Throttle Linkage and Ignition Leads
Connect the Throttle Cable
1.  Loosen the air cleaner cover knob and
remove the air cleaner cover.
See Figure 7.
2. Slip the throttle cable into the cable
adjuster and hook the bullet end of the
cable onto the swivel. See Figure 8.
Connect the Ignition Leads
3. Connect the two ignition wires by
pushing the bullet connectors
together. See Figure 9.
4. Reinstall the air cleaner cover.
Connect the throttle
cable
Ignition
Lead
Figure 8
PB2500.05
PB2500.06
Figure 7
Throttle
Cable
Cable
Adjuster
Filter
Cover
Figure 9
Cable Swivel
CAUTION!
Routing of wiring must not interfere
with throttle operation.